DEFAULT SETTINGS

Output Settings for Input Sources

 

 

Output

Door Relay

Alarm Relay

TTL#1

TTL#2

Buzzer

Input

(DR)

(AR)

(T1)

(T2)

(BZ)

[1]

Exit Button

03

00

00

00

00

[2]

Door Contact

00

99

00

00

00

 

 

 

 

 

 

 

[3]

AUX Input #1

00

00

00

00

00

[4]

AUX Input #2

00

00

00

00

00

 

 

 

 

 

 

[5] TAMPER Alarm

00

99

99

99

99

[6]

Cut Off Alarm

00

00

00

00

00

 

 

 

 

 

 

[7] DURESS ALARM

00

00

00

00

00

[8] ARM/DISARM OUT

00

00

00

00

00

 

 

 

 

 

 

 

[9]

Door Open Timeout

00

99

00

00

00

[10]

Output Time Schedule

00

00

00

00

00

 

 

 

 

 

 

 

[11]

Input Time Schedule

00

00

00

00

00

 

 

 

 

 

 

 

[12]

Cut Off Check

00

00

00

00

00

 

 

 

 

 

 

 

[13]

Input Type

00

00

00

00

00

 

 

 

 

 

 

 

 

1) Index No. [1] ~ [9]

The values indicate the operating time of each output for the input signal. 2) Index No. [10]

The values indicate the time schedule code (index) applied to each output.

3)Index No. [11]

The values indicate the input port ([1]Exit Button ~ [5]Tamper S/W).

Each value indicates the code of Time Schedule to be applied to the corresponding input port.

4)Index No. [12]

The values indicate whether or not to use the cut off check feature for each input. (0 – Not Use, 1 – Use)

5)Index No. [13]

The values indicate whether the input type is NO(Normally Open) or NC(Normally Closed). (0 – NO, 1 – NC)

OTHER INFORMATION

English _ 75

Page 75
Image 75
Samsung SSA-S3010/EXP manual Default Settings, Output Settings for Input Sources, TTL#1 TTL#2, Duress Alarm