Platform Fold Pressure Adjustment

1.Position the platform at the floor level loading position.

2.Loosen the hex nut on the adjustment screw (do not remove hex nut).

3.Turn the adjustment screw counter clockwise until the platform does not fold when the Fold button is pressed.

4.Turn the adjustment screw clockwise in 1/4 turn increments and press the Fold button until the plat- form folds completely (Note: Return the platform to floor level position after each attempt to fold the platform).

5.Turn the adjustment screw an additional 1/8 turn after the platform folds successfully.

6.Tighten the hex nut without moving the adjustment screw.

7.Verify the platform will not stow while occupied.