10

INSTALLATION

INSERT INSTALLATIONS

Insert installations must be vented with 3” or 4” pipe. Pipe may be single wall stainless steel flexible pipe. Vent may terminate within chimney beyond a blanking plate or extend to the chimney top. See “COMBUSTION AIR SUPPLY” for outside air access information.

The fireplace and chimney should be cleaned thoroughly before starting the installation. We suggest painting the interior of particularly old and dirty fireplaces to seal any odors. In zero-clearance fireplace installations, when the fireplace opening is above the floor or raised hearth, the adjustable “Breckwell P2000 Z-C Skirt” (part

#A-ZC-2KSKRT), or “Breckwell P2000 Z-C Legs” (part #A-S-ZCLEGS), can be used to bridge the gap between the hearth and stove bottom. Refer to figure 13.

A.ASSEMBLING THE FLASHING SET

Follow the instructions packaged with the P2000 Flashing set part C-P2KI-SMFL, C- P2KI-MED, or C-P2KI-LG.

(Refer to Figure 14)

FIGURE 13

FIGURE 14

Page 10
Image 10
Breckwell P2000 owner manual Insert Installations, Assembling the Flashing SET