AR60X Installation Manual

suppressor. The surge suppressor must be installed at the point where the DC electrical cable exits/enters the building, however, the use of a surge suppressor at the radio unit is optional since power cable surge suppression is built into the unit.

If a copper Cat5 Ethernet cable is permanently installed, it is necessary to install surge suppressors at both ends of this cable. A surge suppressor must be placed within the radio enclosure (to protect the radio electronics) and at the building exit/entrance (to protect the indoor equipment).

For more information on recommended accessory devices and kits, contact BridgeWave Sales

2.8 Environmental

The structure to which the equipment will be mounted must be adequate to bear all wind and weather conditions. The wind load at high wind velocities can exceed 100 ft/lb of torque, BridgeWave highly recommends pole diameters of 3” or more. The environmental conditions at the location must conform to the operating environment specified for the equipment.