BridgeWave AR60X manual Connecting Network Equipment, Network Port Statistics

Models: AR60X

1 40
Download 40 pages 41.26 Kb
Page 35
Image 35

AR60X Installation Manual

5 Connecting Network Equipment

The user networking equipment that is connected to the radio should be checked to ensure it operates properly over a wired connection. Once this has been confirmed this will save troubleshooting steps after the radio is installed and connected to the network equipment.

We recommend the network equipment on both sides of the link be configured as follows:

1000 Mbps full­duplex

Port auto­negotiation and flow control enabled

Port configured to not enter error­disable state due to link up/down transitions (since these may occur during periods of very heavy rain)

It is possible to disable auto­negotiation on the radio’s fiber interface by use of the built­in Network Management interface. The radio’s 10/100Base­T port is permanently set to auto­ negotiate.

5.1 Network Port Statistics

In the event the network equipment connected to the AR60X offers the capability below, we recommend you verify the following on the network equipment:

Link integrity

There are no receive errors on the link

Network traffic is flowing in both directions.

The radios support all standard Ethernet frame sizes, up to 1632 bytes for un­tagged or 802.1q VLAN­tagged frames.

29

580­00517, rev B

Page 35
Image 35
BridgeWave AR60X manual Connecting Network Equipment, Network Port Statistics