A - Oil Fill Cap — Fill engine with oil here. B - Oil Dipstick — Check engine oil here.
C - Fuel Valve — Used to turn fuel supply on and off to engine.
D - Oil Drain Plug — Drain engine oil here.
E - Hour Meter — Displays and records how many hours your generator has run (up to 9,999.9).
F - Grounding Fastener — Consult your local agency having jurisdiction for grounding requirements in your area.
G - Data Tag — Provides model and serial number of generator. Please have these readily available if calling for assistance.
H - GFCI Circuit Breaker — A GFCI circuit breaker is provided to protect against electrical ground fault and protect the generator against electrical overload.
J - 120/240 Volt AC, 50 Amp Receptacle — May be used to supply electrical power for the operation of 120 and/or 240 Volt AC, 50 Amp, single phase, 60 Hz electrical loads.
K - 120/240 Volt AC, 30 Amp Locking Receptacle — May be used to supply electrical power for the operation of 120 and/or 240 Volt AC, 30 Amp, single phase, 60 Hz electrical, lighting, appliance, tool and motor loads.
L - 120 Volt AC, 30 Amp Locking Receptacle — May be used to supply electrical power for the operation of
120 Volt AC, 30 Amp, single phase, 60 Hz electrical lighting, appliance, tool and motor loads.
M - 120 Volt AC, 20 Amp, Duplex Receptacle — May be used to supply electrical power for the operation of
120 Volt AC, 20 Amp, single phase, 60 Hz electrical, lighting, appliance, tool and motor loads.
N - 12 Volt DC Receptacle — Use this receptacle with battery charge cables to charge a 12 Volt battery. This receptacle is protected by a 10 Amp auto reset circuit breaker.
P - Rocker Switch Circuit Breaker — The 120/240 Volt AC, 30A locking receptacle and the 120 Volt AC, 30A locking receptacle is provided with a 2 pole rocker switch circuit breaker to protect the generator against electrical overload.
R - Idle Control Switch — Use this switch to turn the idle control feature on and off.
S - Run/Stop Switch — Set this switch to "Run" before starting. Set switch to "Stop" to switch off engine.
T - Circuit Breakers (AC) — The 120 Volt AC, 20A duplex receptacle is provided with "push to reset" circuit breakers to protect the generator against electrical overload.
12 | BRIGGSandSTRATTON.COM |