Section 4: Operation
How to Use the Battery Charger
Use battery float charger jack to keep the starting battery charged and ready for use. Battery charging should be done in a dry location, such as inside a garage.
1.Plug charger into unit’s “Battery Float Charger” jack, which is located next to starter switch (Figure 9). Plug battery charger into a 120 Volt AC wall receptacle.
Figure 9 — Battery Charger Jack |
2.Unplug charger from unit and wall outlet when generator is being started and while in operation.
3.Keep this charger plugged in when generator is not in use to prolong battery life.The charger has a built in float equalizer and will not overcharge the battery, even when plugged in for an extended period of time.
IMPORTANT: See “Battery Maintenance” on page 15 for additional information.
COLD WEATHER
OPERATION
Under certain weather conditions (temperatures below 40°F [4°C] combined with high humidity), your generator may experience icing of the carburetor and/or the crankcase breather system.To reduce this problem, you need to perform the following:
1.Make sure generator has clean, fresh fuel.
2.Open fuel valve (turn valve to open position).
3.Use SAE
4.Check oil level daily or after every eight (8) hours of operation.
5.Maintain generator following “Maintenance Schedule” in engine manual.
6.Shelter unit from elements.
In an emergency, use the original shipping carton as a temporary shelter:
7.Cut off all carton flaps.
8.Cut out one long side of carton to expose muffler side of unit as shown in Figure 10.
Figure 10 — Permanent Cold Weather Shelter
Wind |
IMPORTANT: The generator must be at least 5 ft.
(152 cm) from structures having combustible walls and/or other combustible materials. Leave at least 3 ft. (92 cm) all around generator including overhead, for adequate cooling, maintenance and servicing.
WARNING
Running engines produce heat.Temperature of muffler and nearby areas can reach or exceed 150°F (65°C).
Severe burns can occur on contact.
Combustible debris, such as leaves, grass, brush, etc. can catch fire.
•DO NOT touch hot surfaces.
•Allow equipment to cool before touching.
•The generator must be at least 5 feet from structures having combustible walls and/or other combustible materials.
•Keep at least 3 feet of clearance on all sides of generator for adequate cooling, maintenance and servicing.
•Reflective exhaust heat may damage fuel tank causing fire.
•Remove shelter when temperatures are above 40°F [4°C].
9.Cut appropriate slots to access receptacles of unit.
10.Start unit, then place carton over it.
NOTE: Remove shelter when temperatures are above 40°F [4°C].
11