12 Volt DC
Receptacle
Start Switch
Grounding
Fastener
Circuit Breakers (AC) — The 120 Volt AC, 20A duplex receptacles are provided with "push to reset" circuit breakers to protect the generator against electrical overload.
Data Tag – Provides model, revision and serial number of generator. Please have these readily available if calling for assistance.
Fuel Tank — Capacity of seven (7) U.S. gallons. Start Switch — Turn to start the engine.
Grounding Fastener — Consult your local agency having jurisdiction for grounding requirements in your area.
Oil Fill Cap — Add oil to engine here.
Spark Arrester Muffler — Exhaust muffler lowers engine noise and is equipped with a spark arrester screen.
Rocker Switch Circuit Breaker — The 120/240 Volt AC, 30A locking receptacle is provided with a rocker switch circuit breaker to protect the generator against electrical overload. This switch also controls all receptacles.
Choke Lever
Fuel Tank
Rocker Switch Circuit Breaker
Circuit Breakers (AC)
120 Volt AC, 20 Amp
Duplex Receptacles
120/240 Volt AC, 30 Amp Locking Receptacle
Features and Controls Section
2
KNOW YOUR GENERATOR
Read this owner’s manual and safety rules before operating your generator.
Compare this illustration with your generator to familiarize yourself with the locations of various controls and adjustments. Save this manual for future reference.
Oil Fill Cap
Air Cleaner
Spark Arrester Muffler
Data Tag
Battery
12 Volt DC Receptacle — Use this receptacle with battery charge cables to charge a 12 Volt battery.
120 Volt AC, 20 Amp Duplex Receptacles — May be used to supply electrical power for the operation of 120Volt AC, 20 Amp, single phase, 60 Hz electrical lighting, appliance, tool and motor loads.
120/240 Volt AC, 30 Amp Locking Receptacle — May be used to supply electrical power for the operation of 120 and/or 240 Volt AC, 30 Amp, single phase, 60 Hz electrical lighting, appliance, tool and motor loads.
Air Cleaner — Uses a dry type filter element and foam pre–cleaner to limit the amount of dirt and dust sucked into the engine.
Battery — Located behind plastic cover. 12 Volt DC sealed battery provides power to start the engine.
Choke Lever — Used when starting a cold engine.