Briggs & Stratton 30237 owner manual Section Troubleshooting, Problem, Cause, Correction

Models: 30237

1 36
Download 36 pages 60.52 Kb
Page 18
Image 18
Section Troubleshooting

Section Troubleshooting

7

TROUBLESHOOTING

Problem

Cause

Correction

 

 

 

 

 

 

1.

One of the circuit breakers is

1.

Reset circuit breaker.

 

 

open.

 

 

No AC output is available, but

2.

Fault in generator.

2.

Contact Authorized service facility.

3.

Poor connection or defective cord

3.

Check and repair.

generator is running.

 

set.

 

 

 

 

 

 

 

4.

Connected device is bad.

4.

Connect another device that is in

 

 

 

 

good condition.

 

 

 

 

 

Generator runs good at no-load

1.

Short circuit in a connected load.

1.

Disconnect shorted electrical load.

 

 

 

 

but "bogs" down" when loads are

2.

Generator is overloaded.

2.

See "Don't Overload Generator".

connected.

3.

Shorted generator circuit.

3.

Contact Authorized service facility.

 

 

 

 

 

 

 

1.

10 Amp in-line fuse is blown.

1.

Replace fuse.

Generator will not start; or starts

2.

Discharged battery.

2.

Jump start generator and/or charge

and runs rough.

 

 

 

battery.

 

3.

Failed battery.

3.

Replace battery.

 

 

 

Generator shuts down during

Out of gasoline.

Fill fuel tank.

operation.

 

 

 

 

 

 

 

Generator lacks power.

Load is too high.

See "Don't Overload Generator".

 

 

 

 

 

18

Page 18
Image 18
Briggs & Stratton 30237 owner manual Section Troubleshooting, Problem, Cause, Correction