SAFETY RULES

WARNING

Rapid retraction of starter cord (kickback) will pull hand and arm toward engine faster than you can let go.

Broken bones, fractures, bruises or sprains could result.

When starting engine, pull cord slowly until resistance is felt and then pull rapidly to avoid kickback.

NEVER start or stop engine with electrical devices plugged in and turned on.

WARNING

Running engines produce heat.Temperature of muffler and nearby areas can reach or exceed 150°F (65°C).

Severe burns can occur on contact.

Exhaust heat/gases can ignite combustibles, structures or damage fuel tank causing a fire.

DO NOT touch hot surfaces and avoid hot exhaust gases.

Allow equipment to cool before touching.

Keep at least 5 ft. (152 cm) clearance on all sides of generator including overhead.

Code of Federal Regulation (CFR) Title 36 Parks, Forests, and Public Property require equipment powered by an internal combustion engine to have a spark arrester, maintained in effective working order, complying to USDA Forest service standard 5100-1C or later revision. In the State of California a spark arrester is required under section 4442 of the California Public resources code. Other states may have similar laws.

WARNING

Unintentional sparking can result in fire or electric shock.

WHEN ADJUSTING OR MAKING REPAIRS TO YOUR GENERATOR

Disconnect the spark plug wire from the spark plug and place the wire where it cannot contact spark plug.

WHEN TESTING FOR ENGINE SPARK

Use approved spark plug tester.

DO NOT check for spark with spark plug removed.

CAUTION

Excessively high operating speeds increase risk of injury and damage to generator.

Excessively low speeds impose a heavy load.

DO NOT tamper with governed speed. Generator supplies correct rated frequency and voltage when running at governed speed.

DO NOT modify generator in any way.

CAUTION

Exceeding generators wattage/amperage capacity can damage generator and/or electrical devices connected to it.

See “Don’t Overload Generator”.

Start generator and let engine stabilize before connecting electrical loads.

Connect electrical loads in OFF position, then turn ON for operation.

Turn electrical loads OFF and disconnect from generator before stopping generator.

CAUTION

Improper treatment of generator can damage it and shorten its life.

Use generator only for intended uses.

If you have questions about intended use, ask dealer or call 1-800-743-4115.

Operate generator only on level surfaces.

DO NOT expose generator to excessive moisture, dust, dirt, or corrosive vapors.

DO NOT insert any objects through cooling slots.

If connected devices overheat, turn them off and disconnect them from generator.

Shut off generator if:

-electrical output is lost;

-equipment sparks, smokes, or emits flames; -unit vibrates excessively.

4

www.mymowerparts.com

Page 4
Image 4
Briggs & Stratton 30244 manual When Adjusting or Making Repairs to Your Generator, When Testing for Engine Spark

30244 specifications

The Briggs & Stratton 30244 is a prominent portable generator designed to meet the power needs of homeowners and professionals alike. This generator stands out for its reliability, efficiency, and user-friendly features, making it a popular choice for a variety of applications, from powering essential appliances during outages to providing electricity at job sites or outdoor events.

One of the main features of the Briggs & Stratton 30244 is its impressive power output. With a maximum wattage of 7000 watts and a rated wattage of 5500 watts, this generator is capable of running multiple appliances simultaneously. Whether you need to power your refrigerator, lights, or other vital equipment during an outage, the 30244 has the capacity to handle it all. This makes it an ideal backup option for homeowners looking to maintain comfort and safety during unexpected blackouts.

The 30244 also boasts advanced technologies designed to enhance performance and fuel efficiency. It is equipped with a powerful and efficient 306cc engine, offering a balance of power and fuel consumption. This generator features a durable, low-oil shutdown system that protects the engine from damage by automatically turning it off when oil levels are low. Additionally, the generator utilizes a large-capacity fuel tank, which allows for extended run times without frequent refueling, making it convenient for prolonged power needs.

Portability is another key characteristic of the Briggs & Stratton 30244. The generator is designed with a compact and sturdy frame, complemented by a built-in handle and durable wheels, enabling easy transportation to wherever the power is needed. Whether you're moving it around the yard or loading it into a vehicle for a camping trip, its lightweight construction and thoughtful design make portability hassle-free.

Safety features are paramount in the Briggs & Stratton 30244, too. It is equipped with circuit breakers to protect against overloads, ensuring safe operation. Additionally, the generator includes a quiet design that minimizes noise, making it suitable for neighborhood use without causing disturbances.

In conclusion, the Briggs & Stratton 30244 is a versatile, powerful, and user-friendly portable generator. Its robust power output, efficient engine technology, portability, and safety features make it an excellent choice for individuals and families seeking reliable power solutions in various situations. Whether for home use or outdoor activities, this generator is designed to deliver performance and peace of mind.