Image 18
TROUBLE SHOOTING

TROUBLE SHOOTING

Problem:

Burner will not light

Fire at control knob

Yellow Flames at burner

Flame blows out on "LOW"

Burner does not get hot enough

Grill is Too Hot

Possible Causes:

1.Check LP cylinder fuel level.

2.Bad electrode spark.

Check to see if the grill will match light. Electrode or collector may need adjustment.

3.Burner may not be properly seated.

4.Burner may be obstructed.

5.The cylinder valve may be closed.

6.Regulator is not properly seated on cylinder valve.

1.Burner holes may be obstructed. See section on "Burner Assembly/Maintenance" under Proper Care and Maintenance.

2.Burner is improperly seated on control valve.

3.Gas connections may be loose.

Leak Check and tighten all connections.

1.Burner is obstructed. See section on

"Burner Assembly/Maintenance" under Proper Care and Maintenance.

1.Burner holes may be obstructed. See section on "Burner Assembly/Maintenance" under Proper Care and Maintenance.

2.Grill is not sufficiently preheated.

3.Burner is improperly seated on control valve.

1.Flow control device has been activated in regulator. See Regulator Resetting Procedure under Connecting LP Cylinder and Hose/Regulator to Grill.

1.Excess grease build-up causing grease fires.

2.Damaged or faulty regulator. Replace with factory authorized parts.

3.Cook on a lower temperature setting.

17