CHAPTER 8: Regulatory Info. For Smoke Alarms

AGENCY PLACEMENT RECOMMENDATIONS

NFPA Standard 72 Section 2-2.1.1.1

2-2.1.1.1 Smoke alarms shall be installed outside of each separate sleeping area in the immediate vicinity of the bedrooms and on each additional story of the family living unit, including basements and excluding crawl spaces and unfinished attics. In new construction a smoke alarm shall also be installed in each sleeping room. Chapter 2 also reads as follows: 2-2.2.1; In new construction, where more than one smoke alarm is required by 2-2.1, they shall be so arranged that operation of any smoke alarm shall cause the alarm in all smoke alarms within the dwelling to sound. A-2.5.2.1 Smoke Detection — Are More Smoke Alarms Desirable? The required number of smoke alarms may not provide reliable early warning protection for those areas separated by a door from the areas protected by the required alarms. For this reason, it is recommended that the householder consider the use of additional smoke alarms for those areas for increased protection. The additional areas include the basement, bedrooms, dining room, furnace room, utility room, and hallways not protected by the required smoke alarms. The installation of smoke alarms in kitchens, attics (finished or unfinished), or garages is not normally recommended, as these locations occasionally experience conditions that can result in improper operation.

California State Fire Marshall

Early warning detection is best achieved by the installation of fire detection equipment in all rooms and areas of the household as follows: A smoke alarm installed in each separate sleeping area (in the vicinity, but outside bedrooms), and heat or smoke alarms in the living rooms, dining rooms, bedrooms, kitchens, hallways, finished attics, furnace rooms, closets, utility and storage rooms, basements, and attached garages.

IMPORTANT!

This equipment should be installed in accordance with the National Fire Protection Association’s Standard 72. National Fire Protection Association, One Batterymarch Park, Quincy, MA 02269-9101. Additional local building and regulatory codes may apply in your area. Always check compliance requirements before beginning any installation.

Specific requirements for smoke alarm installation vary from state to state and from region to region. Check with your local Fire Department for current requirements in your area. If you install AC or AC/DC units, it is recommended they be interconnected for added protection.

21

Page 23
Image 23
BRK electronic SC1000BN Regulatory Info. For Smoke Alarms, Agency Placement Recommendations, Nfpa Standard 72 Section

SC1000BN specifications

The BRK electronic SC1000BN is a state-of-the-art smoke and carbon monoxide detector designed for enhanced safety in residential and commercial environments. At the heart of its design is the dual sensor technology, which combines both photoelectric and ionization detection methods. This dual system is crucial in detecting a wide range of fire types, from smoldering fires to fast flaming ones. The photoelectric sensor is particularly effective for detecting smoke from smoldering fires, while the ionization sensor effectively detects fast-flaming fires, making this detector a well-rounded solution for various fire scenarios.

A standout feature of the SC1000BN is its sealed lithium battery, which boasts a lifespan of up to 10 years. This eliminates the hassle of battery replacements and ensures that the unit remains operational for a decade. Users can feel secure knowing that the detector will function seamlessly without the need for intervention. Additionally, the detector has a convenient end-of-life signal, alerting users when it’s time to replace the unit itself, ensuring that safety is never compromised.

Another important technology integrated into the SC1000BN is its smart chip technology. This enables the detector to accurately differentiate between various potential threats, reducing false alarms and providing peace of mind to users. The device is also equipped with a loud 85-decibel alarm that ensures occupants are promptly alerted in case of an emergency.

Installation of the SC1000BN is straightforward, with a low-profile design that blends seamlessly into any environment. The unit can be mounted on ceilings or walls, and its aesthetic design complements modern home decor. Furthermore, the detector meets the strictest safety standards, including certification from Underwriters Laboratories (UL), ensuring reliability and efficacy.

In addition to its primary functions, the SC1000BN also features a test/silence button that allows users to check the functionality of the unit or silence false alarms without removing the battery. The combination of advanced detection methods, long-lasting power, and user-friendly features makes the BRK electronic SC1000BN an essential device for enhancing safety and promoting peace of mind in any space. With its commitment to advancing safety technology, BRK electronic continues to be a trusted name in smoke and carbon monoxide detection.