Broan E661 manual Use And Care, Wiring Diagram, Avoid when choosing a detergent

Models: E661

1 36
Download 36 pages 44.84 Kb
Page 11
Image 11
10. USE AND CARE

10. USE AND CARE

Grease filters and bottom panel.

The grease filters and the bottom panel should be cleaned frequently. Use a warm detergent solution. Remove grease filters by pushing them towards the back of hood and rotating downward.

STAINLESS STEEL CLEANING: HOW TO MAINTAIN ITS « BRIGHT LOOK »

Do: - Regularly wash surfaces with clean cloth or rag soaked with warm water and mild soap or liquid dish detergent.

-Always clean in the direction of original polish lines.

-Always rinse well with clear water (2 or 3 times) after cleaning. Wipe completely dry.

-You may also use a specialized household stainless steel cleaner.

Don’t: -Do not use any steel or stainless steel wool or any other scrapers to remove stubborn dirt.

-Do not use any harsh or abrasive cleansers.

-Do not allow dirt to accumulate.

-Do not let plaster dust or any construction residues reach the hood. During construction or renovation, cover the hood to make sure no dust adheres to stainless steel surface.

Avoid: when choosing a detergent

-Any cleaners that contain bleach will attack stainless steel.

-Any products containing : chloride, fluoride, iodide, bromide will deteriorate surfaces rapidly.

-Any combustible products used for cleaning such as acetone, alcohol, ether, benzol, etc., are highly explosive and should never be used close to a range.

ENAMEL FINISH:

Clean with warm water and mild detergent only. If discoloration occurs, use a good enamel polish such as automotive polish. (DO NOT use rough abrasive cleaner or porcelain cleaner).

11. WIRING DIAGRAM

!WARNING

Risk of electrical shock. Electrical wiring must be done by qualified personnel in accordance with all applicable codes and standards. Before connecting wires, switch power off at service panel and lock service disconnecting means to prevent power from being switched on accidentally.

Line 120 V

 

 

 

 

 

 

 

J5

 

 

 

Supply

BK

BK

 

 

 

 

BK

3

nc

 

 

 

 

 

 

 

 

 

2

 

Neutral

W

W

 

 

 

 

W

1

 

 

 

 

 

Light Socket

W

 

 

 

 

J6

 

 

Ground

 

W 50 W max.

 

 

 

 

 

 

 

 

Y

 

 

 

 

Y

3

 

 

 

 

 

 

 

 

 

2

 

 

 

 

 

W

Y

 

 

 

BK

 

 

 

 

 

 

 

 

 

 

nc

1

 

 

 

 

 

W Light Socket

 

 

 

 

 

 

 

 

 

 

50 W max.

 

 

 

 

 

 

 

 

 

 

BN

BK

 

 

 

 

 

 

 

 

 

 

BL

 

 

 

 

 

 

 

 

 

 

BK

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

J4

 

 

 

 

 

 

 

 

 

 

 

 

FAN MOTOR

G

nc

BK

nc Y [120]

BK 4

 

 

 

 

 

 

 

 

R [70]

 

R

3

 

 

 

 

 

 

 

 

P [50]

 

P

2

 

 

 

 

 

 

W

W

BL [35]

 

BL 1

 

 

 

 

 

 

O [0]

nc

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ELECTRONIC

 

 

 

 

 

 

 

 

 

A1

ASSEMBLY

 

 

 

 

 

 

 

 

 

Main power board

J2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

16

 

WIRING COLOR CODE

BK

BLACK

P

PURPLE

BL

BLUE

R

RED

BN

BROWN

W

WHITE

G

GREEN

Y

YELLOW

O

ORANGE

nc

no connection

HE0042A

ELECTRONIC

A2 ASSEMBLY

User Interface

-t° Heat Sentry

NOTES

1.If any of the original wire, as supplied, must be replaced, use the same equivalent wire.

2.Field wiring must comply with applicable codes, ordinances and regulations.

- 11 -

Page 11
Image 11