3.INSTALLATION (CONT’D)

3.7CONNECTING THE DUCTS TO THE UNIT

Insulated flexible ducts

Use the following procedure for connecting the insulated flexible ducts to the port of the unit (Exhaust air to outside and Fresh air from outside ports).

CAUTION

Make sure the balancing dampers are set to their appropriate position before connecting the ducts to the ports. See Section 3.3.

VJ0039

Pull back the insulation to expose the flexible duct.

Rigid ducts

VJ0040

Attach the flexible duct to the port using tie wrap.

VJ0043

Pull the insulation over the joint and tuck in between the inner and outer rings of the double collar.

VJ0041

Pull the vapor barrier over the insulation and over the outer ring of the double collar.

CAUTION

Make sure the vapor barrier on the

insulated ducts does not tear during installation to avoid condensation within the ducts.

VJ0042

Apply duct tape to the joint making an airtight seal.Avoid compressing the insulation when pulling the tape tightly around the joint. Compressed insulation loses its R value and causes water dripping due to condensation on the exterior surface of the duct.

CAUTION

Do not use screws to connect the rigid ducts to the ports.

Use a small length of flexible duct to connect the rigid duct to the ports in order to avoid vibration transmissions. Use tie-wraps to perform connections.

3.8INSTALLING THE TANDEM® TRANSITION KIT

Use the following procedure for connecting the insulated flexible ducts to the Tandem® transition* (Exhaust air to outside and Fresh air from outside).

NOTE: The joist opening needed to install the Tandem® tansition must be 9¾” (248 mm) minimum. Also, the maximum height of the Tandem® transition is 8¾” (222 mm). See Tandem® transition end view beside. If the joist are perpendicular to the ducts, or if the connection to the exterior hood is in a limited area, your installation will need two exterior hoods instead of one. In this case, do not use the Tandem® transition kit. See

next Section 3.9 INSTALLING 2 EXTERIOR HOODS.

*Patent pending.

9 3/4"

248 mm

8 3/4"

222 mm

VD0118

- 13 -

Page 13
Image 13
Broan ERV90HCT Insulated flexible ducts, Rigid ducts, Do not use screws to connect the rigid ducts to the ports

ERV90HCT specifications

The Broan ERV90HCT and HRV90HT are remarkable energy recovery ventilators designed to enhance indoor air quality while promoting energy efficiency in residential settings. Both models are built with innovative technologies that meet the demands of modern homes, ensuring a comfortable living environment.

One of the standout features of the Broan ERV90HCT and HRV90HT is their energy recovery capabilities. They efficiently exchange stale indoor air with fresh outdoor air, recovering up to 90% of the energy that would otherwise be lost. This process not only improves air quality but also helps in reducing heating and cooling costs, making them an excellent investment for energy-conscious homeowners.

Another significant characteristic of both models is their quiet operation. Equipped with advanced fan technology, the ERV90HCT and HRV90HT work at minimal noise levels, ensuring a peaceful indoor atmosphere. Whether in a bedroom, living room, or office, occupants can enjoy the benefits of fresh air without disruptive noise.

The units are designed with user-friendly controls that make operation simple and intuitive. Homeowners can easily adjust settings to optimize airflow based on current needs, whether it’s high ventilation during peak usage times or lower settings for quieter moments. Additionally, the units come with a built-in timer, allowing for customizable operation schedules.

Durability is another hallmark of the Broan ERV90HCT and HRV90HT. Constructed with high-quality materials, these ventilators are designed for long-lasting performance. Furthermore, their compact design allows for flexible installation options, making them suitable for various home layouts and sizes.

The ERV90HCT features a heat recovery system, making it ideal for climates that experience significant temperature fluctuations, while the HRV90HT is tailored for those residing in colder regions. Both units utilize an efficient balanced ventilation system, ensuring that airflow is evenly distributed throughout the home.

In summary, the Broan ERV90HCT and HRV90HT are top-tier energy recovery ventilators that prioritize comfort, efficiency, and air quality. With their energy recovery capabilities, quiet operation, user-friendly controls, durability, and flexible installation options, they stand out in the market as excellent solutions for maintaining a healthy home environment. Whether seeking to reduce energy costs or improve indoor air quality, these models deliver on all fronts, making them a worthy addition to any household.