Broan QS342WW Connect Wiring, Install Hood, from being switched on accidentally, Range Hood, Page

Models: QS330BL QS330WW QS342SS QS342BL QS342WW QS336SS QS330BC QS342BC QS330SS QS336BL

1 16
Download 16 pages 50.04 Kb
Page 5
Image 5
CONNECT WIRING

 

 

ALLURE® QS3 SERIES

 

 

RANGE HOOD

 

 

 

 

 

 

 

 

Page 5

CONNECT WIRING

 

INSTALL HOOD

WARNING: To reduce the risk of electric shock, make sure power is switched off at the service INSTALL HOODfrom being switched on accidentally. panel. Lock or tag service panel to prevent power

from being switched on accidentally.

Manual background HOUSE WIRING (120 VAC)

CARDBOARD (Use to protect cooktop)

1Connect House Wiring (120 VAC) to hood. Use a piece of Manual background Cardboard to protect the cooktop, if necessary.

GREEN

GROUND

Manual background SCREW

2Connect house black to hood black wire, house white to hood Manual background white wire, and house ground under Green Ground Screw.

Securely tighten cable clamp onto house wiring.

KEYHOLE (4)

MOUNTING SCREW (4)

1 Hang hood from (4) Mounting Screws. Slide hood towards Manual background wall until mounting screws are engaged in narrow end of

(4)Keyholes. Tighten mounting screws securely. A long screwdriver works best.

2

Replace bottom cover.

DUCT

Manual background TAPE

3 Connect ductwork to hood. Use Duct Tape to make joints Manual background secure and air tight.

PAR20,

50W MAX.

HALOGEN

BULB (2)

- or - R16, 40W MAX.

INCANDESCENT

BULB (2)

4 Install (2) PAR20, 50 W Maximum Halogen Bulbs or (2) Manual background R16, 40 W Maximum Incandescent Bulbs. Purchase bulbs

separately.

!CAUTION: Bulbs may be hot! Refer to bulb packaging Manual background for further information.

5 Replace filters, turn on power at service panel, and test for Manual background proper operation.

Page 5
Image 5
Broan QS342WW Connect Wiring, Install Hood, from being switched on accidentally, ALLURE QS3 SERIES, Range Hood, Page