Broan QSE1 warranty Connect Wiring, Install Hood, power from being switched on accidentally, Page

Models: QSE1

1 12
Download 12 pages 26.73 Kb
Page 4
Image 4
CONNECT WIRING

ALLURE® QSE1 SERIES RANGE HOOD

Page 4

CONNECT WIRING

WARNING: To reduce the risk of electric shock, make sure power is switched off at the service power from being switched on accidentally.INSTALL HOOD panel. Lock or tag service panel to prevent

power from being switched on accidentally.

GREEN

GROUND

Manual background SCREW

INSTALL HOOD

KEYHOLE

(4)

MOUNTING

SCREW

(4)

1 Hang hood from (4) Mounting Screws (from parts bag). Manual background Slide hood towards wall until mounting screws are engaged in narrow end of (4) Keyholes. Tighten mounting screws

securely.

1Connect House Wiring (120 VAC) to hood. Connect house Manual background black to hood black wire, house white to hood white wire, and house ground under Green Ground Screw. Securely

tighten cable clamp onto house wiring.

2 Manual background Replace wiring cover.

CAUTION

DO NOT PUSH ON FAN BLADE. Pushing on the blade may cause it to interfere with other hood parts.

DUCT

TAPE

2

Connect ductwork to hood. Use Duct Tape to make joints secure and air tight.

Page 4
Image 4
Broan Connect Wiring, Install Hood, power from being switched on accidentally, ALLURE QSE1 SERIES RANGE HOOD, Page