ALLURE® QSE1 SERIES RANGE HOOD
Page 4
CONNECT WIRING
WARNING: To reduce the risk of electric shock, make sure power is switched off at the service panel. Lock or tag service panel to prevent
power from being switched on accidentally.
GREEN
GROUND
SCREW
INSTALL HOOD
KEYHOLE
(4)
MOUNTING
SCREW
(4)
1 Hang hood from (4) Mounting Screws (from parts bag). Slide hood towards wall until mounting screws are engaged in narrow end of (4) Keyholes. Tighten mounting screws
securely.
1Connect House Wiring (120 VAC) to hood. Connect house black to hood black wire, house white to hood white wire, and house ground under Green Ground Screw. Securely
tighten cable clamp onto house wiring.
2 Replace wiring cover.
CAUTION
DO NOT PUSH ON FAN BLADE. Pushing on the blade may cause it to interfere with other hood parts.
DUCT
TAPE
2 |
Connect ductwork to hood. Use Duct Tape to make joints secure and air tight.