INSTALL MOUNTING BRACKET
1.Construct wood wall framing that is flush with interior surface of wall studs.
Make sure:
a)the framing is centered over installation location.
b)the height of the framing will allow the mounting bracket to be secured to the framing within the dimensions shown.
2.After wall surface is finished, secure mounting bracket to framing using dimensions shown.
NOTE:
-On 8’ ceilings, the hood distance above cook top is :
minimum 24”, maximum 28” (for Ducted Configuration).
minimum 24”, maximum 27” (for
-On 9’ ceilings, the hood distance above cook top is :
-minimum 28”, maximum 30” (the air vents on the upper flue will be exposed
after installation).
INSTALL FLUE MOUNTING BRACKET
DUCTEDANDNON-DUCTED
1.Assemble the flue mounting bracket, adjusting outside width as shown. Fig.5
2.Carefully center the mounting bracket directly over the range hood location.
3.Secure the bracket assembly to the ceiling using (2) 4.8x38mm mounting screws and drywall anchors. Make sure the bracket is pushed into the corner, tight against the wall and centered over the hood.
PREPARE THE HOOD
Note: On stainless steel hoods, carefully remove the plastic protective film from all exterior surfaces of the hood and decorative flues, prior to final installation.
DUCTED CONFIGURATION
1.Install the discharge collar into the duct connector of the range hood. Fig.6
FRAMING BEHIND DRYWALL
36 | 3/4” | to |
|
| |
|
|
| |||
cooktop | 42 3/4” | above | |||
| |||||
|
|
|
|
36 3/4"= bottom of hood 24" above cooktop
42 3/4"= bottom of hood 30" above cooktop
| fig.4 |
FLUE MOUNTING |
|
BRACKET | 3.9 x 6mm |
| FLAT HEAD |
| BRACKET SCREWS |
7 - 3/4” |
|
(197mm) |
|
| fig.5 |
6” |
|
DIAMETER |
|
DUCT |
|
DISCHARGE |
|
COLLAR |
|
DUCT |
|
CONNECTOR |
|
| fig.6 |
6