Brocade Communications Systems 8770-4 quick start Inserting a switch fabric module, 15 of

Models: 8770-4

1 32
Download 32 pages 24.78 Kb
Page 15
Image 15
Inserting a switch fabric module

FIGURE 5 Inserting a management module

Inserting a switch fabric module

For this procedure, refer to “ESD precautions” and Figure 6.

Complete the following steps to insert the SFM.

1.Unpack the new SFM and remove it from the anti-static bag.

2.Inspect the module for damage.

3.Remove the protective caps from the backplane connectors.

4.Unscrew the power enable pin, pull it outward, and move the slider toward the center of the module face.

5.Open the ejectors on the new SFM by rotating them toward the center of the module face. Orient the switch fabric module so that the ejectors are toward you.

6.Align the module pan with the guides in the slot. The first SFM ashould be installed in slot S1.

7.Push the SFM firmly into the slot.

8.Close the ejectors by rotating them away from the center of the SFM. The levering action of the ejectors seats the module in the slot.

9.Tighten the captive screws using the Phillips screwdriver.

10.Pull out the power enable pin and move the slider all the way to the right.

11.Screw in the power enable pin.

12.Tighten the screws on the slider.

Brocade VDX 8770-4 QuickStart Guide