Brocade ICX 6650 Layer 3 Routing Configuration Guide 449
53-1002603-01
Displaying VRRP and VRRP-E information
The following example is for a VRRP Backup.
The following example is for a VRRP-E Master.
Syntax: show ip vrrp brief | ethernet stack-unit/slotnum/portnum | ve num | stat
Syntax: show ip vrrp-extended brief | ethernet stack-unit/slotnum/portnum | ve num | stat
The brief option displays summary information. Refer to “Displaying summary information” on
page4 46.
The ethernet portnum option specifies an Ethernet port. If you use this option, the command
displays VRRP or VRRP-E information only for the specified port. Also, you must specify the slotnum
variable on chassis devices.
Brocade#show ip vrrp
Total number of VRRP routers defined: 1
Interface ethernet v3
auth-type simple text password
VRID 3
state backup
administrative-status enabled
mode non-owner(backup)
priority 110
current priority 110
hello-interval 1000 msec
dead-interval 0 msec
current dead-interval 3500 msec
preempt-mode true
ip-address 192.168.3.1
virtual mac address 0000.0000.0103
advertise backup: enabled
next hello sent in 00:00:26.1
master router 192.168.3.1 expires in 00:00:02.7
track-port 1/2/1-1/2/4(up)
Brocade#show ip vrrp-extended
Total number of VRRP-Extended routers defined: 50
Interface ethernet v201
auth-type simple text password
VRID 201
state master
administrative-status enabled
priority 220
current priority 220
hello-interval 1000 msec
dead-interval 0 msec
current dead-interval 3100 msec
preempt-mode true
virtual ip address 10.201.201.5
virtual mac address 0000.00d7.82c9
advertise backup: enabled
next hello sent in 00:00:00.1
backup router 10.201.201.4 expires in 00:02:45.2
backup router 10.201.201.3 expires in 00:02:47.6
track-port 1/1/5*1/1/24(up)