GAS CONVERSION TO NATURAL GAS
1.R3B Grills: Remove cooking grids, briquets and briquet rack from grill.
2.Blue Flame Burner: Remove blue flame burner shield and blue flame burner from grill (one (1)
3.Remove LP burner orifices marked 1.25 mm for R3B. Re- move LP burner orifice marked 1.3 mm for R3. See Figure 37.
R3B |
R3 |
Figure 36 |
Figure 37
4.Install natural gas burner orifice marked 49 into each orifice fitting. Apply pipe compound to threads on orifices prior to in- stallation.
5.Blue Flame Burner: Place burner shield and burners into grill and insert burner tubes over orifice fittings. Secure each burner with one (1)
Infrared Burner: Place infrared burners, ignitor, and lugs into grill and insert burner tubes over orifice fittings. Secure each burner with one (1)
6.Grasp valve knobs and remove from valves.
7.The low input adjustment screws are located inside the two valve stems. Use a small screwdriver to turn each adjustment screw clockwise 1/4 turn (90 degrees). When valves are in the "OFF" position, the slot in the adjustment screw should be vertical. See Figure 38.
ADJUSTMENT SCREW | ADJUSTMENT SCREW |
NAT LPG
Figure 38
8.Remove the hose and regulator from the gas connection on grill with adjustable wrench.
9.Connect the grill to the natural gas supply.
Attention: Before lighting your grill check all gas con- nections including the adjustment screws in valve stems for gas leaks with a soapy water mixture.
Caution: Do not use the grill if a gas leak is detected until gas leak is corrected. If a gas leak can not be stopped, do not use grill. You must contact a qualified repair person.
10.Push valve knobs onto valves.
11.Apply the completed conversion label adjacent to the rating plate label on the grill.
Page 42 |