9-4 BE-1204B-BC • BE-1206B-BC
Chapter 9 Error code list
Code Error Messages Error Measures
E-2A Area over Hoop overhang (+Y, -Y)
E-2B Area over Hoop overhang (+X, +Y, -Y)
E-2C Area over Hoop overhang (-X, -Y)
E-2D Area over Hoop overhang (+X, -X, -Y)
E-2E Area over Hoop overhang (-X, +Y, -Y)
E-2F Area over Hoop overhang (+X, -X, +Y, -Y)
E-31 Area over Needle overhang (+X)
E-32 Area over Needle overhang (+Y)
E-33 Area over Needle overhang (+X, +Y)
E-34 Area over Needle overhang (-X)
E-36 Area over Needle overhang (-X, +Y)
E-38 Area over Needle overhang (-Y)
E-39 Area over Needle overhang (+X, -Y)
E-3C Area over Needle overhang (-X, -Y)
Pattern or the needle position is out of the
embroidering area. Reset the embroidering
area on the panel or move the hoop to the
sewable position.
E-40
Remove unused
presser foot, or it may
be damaged
The status of presser foot is issued
as an alarm when every second
machine is used.
E-41
This function is not
supported. Turn off the
power
Invalid start-up error
This is not displayed in this model.
E-42 XY movement error XY movement error
Press the or turn on the F/B switch on the
head to either side. If this error occurs frequently,
check if the tension of the pulley belt is proper.
E-43 Slave I/F EEPROM
read error
I/F CPU failed to read EEPROM
data
Turn the power off and on once. If the same
error occurs again, the main PC is faulty.
E-44 Inter-head CPU
communication error
Failed in the communication with
inter-head CPU
Press the or turn ON the F/B switch on the
head to either side. If the same error occurs
again, the connector of communication cable on
the inter-head CPU may be disconnected.
E-45 Head CPU
communication error
Failed in the communication with
head CPU
Press the or turn ON the F/B switch on the
head to either side. If the same error occurs
again, the connector of communication cable on
the head CPU may be disconnected.
E-46 XY CPU communication
error
Failed in the communication with
XY CPU
Press the or turn ON the F/B switch on the
head to either side. If the same error occurs
again, the main PCB is faulty.
E-47 I/F CPU communication
error
Failed in the communication with
I/F CPU
Press the or turn ON the F/B switch on the
head to either side. If the same error occurs
again, the main PCB is faulty.
E-48 Main shaft rotation
abnormal
The main shaft rotated the
opposite way
Turn OFF the power and check if the sensors of
the encoder A and B are connected correctly, not
mixed-up each other. If those connections are
correct, then check if the pin connections of the
main shaft motor connectors are correct.