BE-1204B-BC • BE-1206B-BC 9-7
Chapter 9 Error code list
Code Error Messages Error Measures
E-D5 Needle bar case motor
overcurrent Needle bar case motor overcurrent
Turn OFF the power. The possible causes for this
error are, troubles of the needle bar case motor,
troubles of the main PCB, and troubles of the
drive PCB.
E-D6 Jump motor overcurrent Jump motor overcurrent
Turn OFF the power. The possible causes for this
error are troubles of the jump motor and troubles
of the head PCB.
E-D7 Temperature rise error
Clean the fan filter
The temperature of the heat sink
on the drive PCB rose excessively
Turn OFF the power and check if the fan filter has
any clogging.
E-D8 Temperature sensor
abnormal Temperature sensor abnormal
Turn OFF the power. The possible causes for this
error are troubles of the thermistor and troubles
of the drive PCB.
E-E1
X-axis pulse motor
overcurrent stop
Turn off the power
X-axis pulse motor overcurrent
stop
E-E2
Y-axis pulse motor
overcurrent stop
Turn off the power
Y-axis pulse motor overcurrent
stop
Turn OFF the power and ON once. If the same
error occurs again, the pulse motor or the drive
PCB is faulty.
E-E3 Exhaust fan motor stop Cooling fan motor stop A Press R.
Turn OFF the power and check the fan harness.
Turn OFF the power again. If the same error
occurs again, the fan or the power PCB is faultly.
E-E4 Hook motor error Lower shaft communication error This is not displayed in this model.
E-E5 ERROR E5 Over-run error during interfacing to
main PCB CPU
E-E6 ERROR E6 Framing error during interfacing to
main PCB CPU
E-E7 ERROR E7 Parity error during interfacing to
main PCB CPU
E-E8 ERROR E8 Receiving time up error during
interfacing to main PCB CPU
E-E9 ERROR E9
Send/Receive inconsistent error
during interfacing to main PCB
CPU
E-EA ERROR EA ACK code receiving error during
interfacing to main PCB CPU
E-EB ERROR EB Send/Receive ID code error during
interfacing to main PCB CPU
E-EC ERROR EC Send data checksum error during
interfacing to main PCB CPU
E-ED ERROR ED Data empty error during interfacing
to main PCB CPU
E-EE ERROR EE Abnormal data received in the
inner-machine communication
E-EF ERROR EF Receiving error on interface
E-F1 ERROR F1 Receive time up error
E-F2 ERROR F2 Request-to-waiting time up error
E-F3 ERROR F3 Request-to-receive time up error
E-F4 ERROR F4 Receive command error
E-F5 ERROR F5 NACK code receiving error
E-F6 ERROR F6 Data requested for needle position
can not be returned.
E-F7 ERROR F7 It is not receive command for the
request one.
E-F8 ERROR F8 PRE code error
This is not usually displayed.