BES-941BC • BES-1241BC 95
Chapter 5 Setting
4. Input sensitivity of the thread breakage sensor.
5. Press
END
.
Modified setting is saved and the previous screen is displayed again.
Automatic Step-Back
The number of stitches to step back automatically in case of a thread breakage can
be set.
Setting can be done within the range of 0 ~ 10 stitches.
This function is previously set to 0 stitches upon shipments.
1. Press twice.
2. Select by pressing .
3. Input the number of stitches to step back automatically by pressing ten
keys.
Pressing sets whether to execute an extra step-back by a sensitivity amount of the thread
breakage sensor in the automatic step-back mode.
When stepping back by a sensitivity
amount of the thread breakage sensor
When stepping back by preset number of
stitches
4. Press
END
.
Modified setting is saved and the previous screen is displayed again.
Total number of stitches to step back in
the automatic step-back mode