CHAPTER 5 MAINTENANCE
5-24
Replacing the Fusing Unit
1. Press the Power button to turn off the printer. Unplug the printer. To
avoid injury, wait until the printer has cooled down sufficiently before you
replace the Fusing Unit.
2. Open the Top Cover.
3. Unscrew the two long screws
as shown to release the Fusing
Unit from the printer.
Fig. 5-20
Note
If you begin using a new Fusing Unit immediately, poor print quality may
result. Please wait for 30 minutes after installing a new Fusing Unit to
allow the oil to circulate completely through to the Heat Roller.
4. Hold the handles on both sides
as you remove the Fusing Unit
from the printer.
Fig. 5-21