213A

COMBINATION RATINGS

 

 

 

 

 

 

 

 

ARI Standard Ratings

 

 

 

Unit

 

Cooling

 

Cooling

 

 

 

 

Heating

 

 

 

Size ---

Indoor Model

Capacity

Factory

Standard

 

SEER

 

High Temp

Low Temp

 

Furnace Model

Series

 

 

EER

 

 

 

 

HSPF

 

 

Enhance

Rating

 

TDR

E

E

H

H

 

 

 

 

 

 

Capacity

COP

Capacity

COP

 

 

 

 

 

 

 

 

 

 

 

 

 

*FY4ANF018

17,100

TDR&TXV

13.00

 

 

10.50

18,000

3.36

10,900

2.24

7.7

 

 

FF1ENP018

17,100

TDR&TXV

13.00

 

 

10.50

18,000

3.38

10,900

2.26

7.7

 

 

FF1ENP024

17,400

TDR&TXV

13.20

 

 

10.70

17,900

3.44

10,900

2.28

7.7

 

 

FV4BNF002

17,700

TDR&TXV

14.00

 

 

12.00

17,200

3.64

10,500

2.48

8.2

 

 

FX4CNF018

17,500

TDR&TXV

14.00

 

 

11.70

17,600

3.60

10,500

2.38

8.0

 

 

FX4CNF024

17,700

TDR&TXV

14.00

 

 

12.00

17,400

3.66

10,500

2.42

8.1

 

 

FY4ANF024

17,200

TDR&TXV

13.00

 

 

10.50

17,900

3.38

11,000

2.26

7.7

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CAP**1814A**

17,000

TDR&TXV

14.00

 

 

11.70

17,100

3.34

10,200

2.30

7.7

315(A,J)AV036070

 

CAP**1814A**

17,000

TXV

 

 

13.00

10.50

18,000

3.32

10,900

2.24

7.7

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CAP**2414A**

17,300

TDR&TXV

14.00

 

 

11.70

17,300

3.50

10,300

2.36

7.8

315(A,J)AV036070

 

CAP**2414A**

17,400

TXV

 

 

13.00

10.80

18,000

3.48

11,000

2.30

7.7

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CAP**2417A**

17,400

TDR&TXV

14.00

 

 

12.00

17,200

3.54

10,300

2.38

7.8

315(A,J)AV048090

 

CAP**2417A**

17,300

TDR&TXV

14.00

 

 

11.70

17,300

3.52

10,300

2.36

7.9

355AAV042060

 

CAP**2417A**

17,400

TXV

 

 

13.00

10.80

18,000

3.48

11,000

2.30

7.7

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CNPF*2418A**

17,400

TXV

 

 

13.00

10.80

18,000

3.54

11,000

2.30

7.8

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

018---A

CNPH*2417A**

17,300

TDR&TXV

14.00

 

 

11.70

17,300

3.54

10,300

2.38

7.8

315(A,J)AV036070

CNPH*2417A**

17,400

TDR&TXV

14.00

 

 

11.70

17,300

3.58

10,300

2.38

7.9

315(A,J)AV048090

 

 

 

 

CNPH*2417A**

17,300

TDR&TXV

14.00

 

 

11.70

17,300

3.56

10,300

2.38

7.9

355AAV042040

 

CNPH*2417A**

17,300

TDR&TXV

14.00

 

 

11.70

17,300

3.58

10,300

2.38

7.9

355AAV042060

 

CNPH*2417A**

17,400

TDR&TXV

14.00

 

 

11.70

17,300

3.58

10,300

2.38

7.9

355AAV042080

 

CNPH*2417A**

17,400

TXV

 

 

13.00

10.80

18,000

3.54

11,000

2.30

7.8

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CNPV*1814A**

17,000

TDR&TXV

14.00

 

 

11.70

17,100

3.48

10,300

2.34

7.7

315(A,J)AV036070

 

CNPV*1814A**

17,000

TXV

 

 

13.00

10.80

18,000

3.48

10,900

2.28

7.7

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CNPV*2414A**

17,300

TDR&TXV

14.00

 

 

11.70

17,300

3.54

10,300

2.38

7.8

315(A,J)AV036070

 

CNPV*2414A**

17,400

TXV

 

 

13.00

10.80

18,000

3.54

11,000

2.30

7.8

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CNPV*2417A**

17,400

TDR&TXV

14.00

 

 

11.70

17,300

3.60

10,300

2.38

7.9

315(A,J)AV048090

 

CNPV*2417A**

17,300

TDR&TXV

14.00

 

 

11.70

17,300

3.56

10,300

2.38

7.9

355AAV042060

 

CNPV*2417A**

17,400

TXV

 

 

13.00

10.80

18,000

3.54

11,000

2.30

7.8

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CSPH*2412A**

17,300

TDR&TXV

14.00

 

 

11.70

17,300

3.56

10,300

2.38

7.9

315(A,J)AV036070

 

CSPH*2412A**

17,300

TDR&TXV

14.00

 

 

12.00

17,300

3.58

10,300

2.38

7.9

315(A,J)AV048090

 

CSPH*2412A**

17,300

TDR&TXV

14.00

 

 

11.70

17,300

3.58

10,300

2.38

7.9

355AAV042040

 

CSPH*2412A**

17,300

TDR&TXV

14.00

 

 

12.00

17,300

3.58

10,300

2.38

7.9

355AAV042060

 

CSPH*2412A**

17,300

TDR&TXV

14.00

 

 

11.70

17,300

3.58

10,400

2.38

7.9

355AAV042080

 

CSPH*2412A**

17,400

TXV

 

 

13.00

10.80

17,800

3.50

11,000

2.32

7.8

 

 

*FY4ANF024

22,600

TDR&TXV

13.00

 

 

10.50

24,000

3.54

15,000

2.48

8.2

 

 

FF1ENP024

22,800

TDR&TXV

13.00

 

 

10.70

24,000

3.56

15,200

2.46

8.2

 

 

FF1ENP030

22,800

TDR&TXV

13.00

 

 

10.40

24,200

3.56

15,100

2.48

8.0

 

 

FV4BNF002

23,200

TDR&TXV

14.00

 

 

11.70

23,200

3.80

14,400

2.66

8.5

 

 

FV4BNF003

23,400

TDR&TXV

14.00

 

 

12.00

23,000

3.78

14,300

2.66

8.5

 

 

FX4CNF024

23,000

TDR&TXV

14.00

 

 

11.40

23,800

3.72

14,600

2.60

8.3

 

 

FX4CNF030

23,400

TDR&TXV

14.00

 

 

11.70

23,600

3.84

14,600

2.66

8.5

 

 

FY4ANF030

23,000

TDR&TXV

13.20

 

 

10.60

24,000

3.64

15,100

2.52

8.4

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CAP**2414A**

22,600

TDR&TXV

14.00

 

 

11.50

23,400

3.62

14,300

2.58

8.3

315(A,J)AV036070

 

CAP**2414A**

22,800

TXV

 

 

13.00

10.50

24,400

3.60

15,100

2.50

8.3

 

024---A

 

 

 

 

 

 

 

 

 

 

 

 

 

CAP**2417A**

22,800

TDR&TXV

14.00

 

 

11.70

23,400

3.66

14,300

2.60

8.4

315(A,J)AV048090

 

CAP**2417A**

22,800

TDR&TXV

14.00

 

 

11.70

23,400

3.64

14,300

2.58

8.4

355AAV042060

 

CAP**2417A**

22,800

TXV

 

 

13.00

10.50

24,400

3.60

15,100

2.50

8.3

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CAP**3014A**

23,000

TDR&TXV

14.00

 

 

11.70

23,000

3.64

14,400

2.60

8.4

315(A,J)AV036070

 

CAP**3014A**

23,000

TXV

 

 

13.00

10.60

23,400

3.56

15,200

2.52

8.3

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CAP**3017A**

23,000

TDR&TXV

14.00

 

 

11.70

23,000

3.68

14,300

2.62

8.5

315(A,J)AV048090

 

CAP**3017A**

23,000

TDR&TXV

14.00

 

 

11.70

23,000

3.68

14,300

2.62

8.5

355AAV042060

 

CAP**3017A**

23,000

TXV

 

 

13.00

10.60

23,400

3.56

15,200

2.52

8.3

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CNPF*2418A**

22,800

TXV

 

 

13.00

10.50

24,400

3.68

15,200

2.52

8.5

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CNPH*2417A**

22,600

TDR&TXV

14.00

 

 

11.50

23,600

3.68

14,400

2.58

8.4

315(A,J)AV036070

See note on pg. 17

10

Page 10
Image 10
Bryant 213A warranty Combination Ratings, High Temp Low Temp Furnace Model Series, Enhance Rating, 018---A, 024---A

213A specifications

The Bryant 213A is a cutting-edge system known for its impressive performance and reliability in heating and cooling applications. Designed for residential and light commercial use, it stands out due to its efficiency and innovative features, making it a popular choice among homeowners and contractors alike.

One of the main features of the Bryant 213A is its advanced two-stage cooling and heating capability. This allows for more precise temperature control and enhanced comfort. By adjusting its output based on the current demand, the unit operates at lower speeds during moderate conditions, which helps in saving energy while still maintaining desired comfort levels.

Efficiency is another hallmark of the Bryant 213A. It boasts a high Seasonal Energy Efficiency Ratio (SEER) and Energy Efficiency Ratio (EER), making it one of the most energy-efficient systems in the market. This efficiency not only contributes to lower energy bills but also helps in reducing the environmental footprint of the home, making it a greener choice for those conscious of their energy consumption.

The 213A leverages state-of-the-art technology such as a variable-speed compressor and advanced refrigerant management. This technology facilitates smooth operation and minimizes temperature fluctuations. Additionally, the unit is designed for quiet operation, which means it can efficiently cool or heat a home without intrusive noise, resulting in a more comfortable living environment.

Installation flexibility is another significant advantage of the Bryant 213A. The system is compatible with various ductwork configurations and can be easily integrated into existing HVAC systems. This adaptability makes it suitable for different home sizes and layouts, providing solutions for both new constructions and retrofits.

Durability is a core characteristic of the Bryant 213A. Crafted with high-quality materials and backed by a robust warranty, it ensures longevity and dependable performance. The unit is built to withstand various weather conditions and is designed with low maintenance in mind, further enhancing its appeal.

In conclusion, the Bryant 213A combines efficiency, advanced technology, and durability, making it an exceptional choice for heating and cooling needs. Its innovative features, quiet operation, and adaptability to different home environments set it apart in the HVAC landscape. Selecting the Bryant 213A ensures a comfortable, energy-efficient, and reliable climate control solution for any modern home.