MODEL NUMBER NOMENCLATURE
1 | 2 | 3 | 4 | 5 | 6 | 7 | 8 | 9 | 10 | 11 | 12 | 14 |
N | N | N | A | A/N | N | N | N | N | A/N | A/N | N | A |
2 | 1 | 3 | A | N | A | 0 | 3 | 6 | 0 | 0 | 0 | 0 |
Product | Tier | SEER | Major | Voltage | Variations | Cooling Capacity | Open | Open | Open | Minor | ||
Family |
|
| Series |
|
|
|
|
|
|
|
| Series |
2=HP | 1= | 3=13 SEER | A=Puron | N= | A = Standard |
|
|
| 0=Not | 0=Not | 0=Not | A = |
| Legacy |
|
| or |
|
|
|
| Defined | Defined | Defined | Original |
| RNC |
|
|
|
|
|
|
|
|
|
| Series |
213A
|
|
| ISO 9001:2000 |
|
|
|
|
|
|
|
| ||
the environmentally sound refrigerant |
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
| REGISTERED |
|
|
|
|
|
|
|
| |||
|
|
|
|
|
|
| As an Energy Star→ Partner, Bryant Heating |
| |||||
|
|
|
|
|
|
| & Cooling systems has determined that this |
| |||||
|
|
|
|
|
|
| product meets the ENERGY STAR→ |
|
| ||||
|
|
|
|
|
|
| guidelines for energy efficiency. |
|
| ||||
|
|
|
|
|
|
| Refer to the combination ratings in Product |
|
| ||||
|
|
|
|
|
|
| Data for system combinations that meet |
|
| ||||
|
|
|
|
|
|
| Energy Star guidelines. |
|
|
|
| ||
| STANDARD FEATURES |
|
|
|
|
|
|
| |||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Feature |
| 18 | 24 |
|
| 30 |
| 36 |
| 42 |
| 48 | 60 |
|
|
|
|
|
|
|
|
|
|
|
|
| |
Puron Refrigerant |
| X | X |
| X |
| X |
| X |
| X | X | |
|
|
|
|
|
|
|
|
|
|
|
|
| |
13 SEER |
| X | X |
| X |
| X |
| X |
| X | X | |
|
|
|
|
|
|
|
|
|
|
|
|
| |
Scroll Compressor |
| X | X |
| X |
| X |
| X |
| X | X | |
|
|
|
|
|
|
|
|
|
|
|
|
| |
Dense Wire Coil Guard |
| X | X |
| X |
| X |
| X |
| X | X | |
|
|
|
|
|
|
|
|
|
|
|
|
| |
Field Installed Filter Drier |
| X | X |
| X |
| X |
| X |
| X | X | |
|
|
|
|
|
|
|
|
|
|
|
|
| |
Front Seating Service Valves |
| X | X |
| X |
| X |
| X |
| X | X | |
|
|
|
|
|
|
|
|
|
|
|
|
| |
Internal Pressure Relief Valve |
| X | X |
| X |
| X |
| X |
| X | X | |
|
|
|
|
|
|
|
|
|
|
|
|
| |
Internal Thermal Overload |
| X | X |
| X |
| X |
| X |
| X | X | |
|
|
|
|
|
|
|
|
|
|
|
|
| |
Long Line capability |
| X | X |
| X |
| X |
| X |
| X | X | |
|
|
|
|
|
|
|
|
|
|
|
|
| |
Low Ambient capability with Kit |
| X | X |
| X |
| X |
| X |
| X | X | |
|
|
|
|
|
|
|
|
|
|
|
|
| |
Suction Line Accumulator |
| X | X |
| X |
| X |
| X |
| X | X | |
|
|
|
|
|
|
|
|
|
|
|
|
| |
High Pressure Switch |
| X | X |
| X |
| X |
| X |
| X | X | |
|
|
|
|
|
|
|
|
|
|
|
|
| |
Loss of Charge Switch |
| X | X |
|
| X |
| X |
| X |
| X | X |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
2