Bryant 213A warranty Physical Data, Vapor Line Sizing And Cooling Capacity Loss

Models: 213A

1 32
Download 32 pages 35.64 Kb
Page 3
Image 3
PHYSICAL DATA

PHYSICAL DATA

UNIT SIZE SERIES

018---A

024---A

030---A

 

036---A

 

042---A

048---A

060---A

Operating Weight (lb)

146

162

203

 

207

 

246

263

279

Shipping Weight (lb)

169

189

235

 

239

 

278

293

311

Compressor Type

 

 

 

 

Scroll

 

 

 

REFRIGERANT

 

 

 

Puron(R--- 410A)

 

 

 

Control

 

 

TXV (Puron Hard Shutoff)

 

 

Charge (lb)

5.25

5.9

7.6

 

7.65

 

8.4

11.75

12.35

COND FAN

 

 

Propeller Type, Direct Drive

 

 

Air Discharge

 

 

 

 

Vertical

 

 

 

Air Qty. (CFM)

2196

2614

2614

 

3365

 

3810

4046

4046

Motor HP

1/10

1/10

1/10

 

1/4

 

1/5

1/5

1/5

Motor RPM

1100

1100

1100

 

1100

 

800

800

800

COND COIL

 

 

 

 

 

 

 

 

 

Face Area (Sq. ft.)

13.13

15.09

25.87

 

25.87

 

25.15

20.12

22.63

Fins per In.

25

20

20

 

20

 

20

20

20

Rows

1

1

1

 

1

 

1

2

2

Circuits

4

5

6

 

6

 

6

8

8

VALVE CONNECT. (In. ID)

 

 

 

 

 

 

 

 

 

Vapor

5/8

5/8

3/4

 

3/4

 

7/8

7/8

7/8

Liquid

 

 

 

3/8

 

 

 

 

REFRIGERANT TUBES* (In. OD)

 

 

 

 

 

 

 

 

 

Vapor (0---80 ft. Tube Length)

5/8

5/8

3/4

 

3/4

 

7/8

7/8

1--- 1/8

Liquid (0---80 ft. Tube Length)

 

 

 

3/8

 

 

 

 

*For tubing sets between 80 and 200 ft. horizontal or 20 ft. vertical differential, consult the Longline Guideline. Note: See unit Installation Instruction for proper installation.

VAPOR LINE SIZING AND COOLING CAPACITY LOSS

PURON 1-STAGE HEAT PUMP APPLICATIONS

LONG LINE APPLICATION: An application is considered

is above indoor unit, and 80 ft. when the outdoor unit is below

”Long line” when the total equivalent tubing length exceeds 80

the indoor unit. Refer to Accessory Usage Guideline below for

ft. or when there is more than 20 ft. vertical separation between

required accessories. See Longline Application Guideline for

indoor and outdoor units. These applications require additional

required piping and system modifications. Also, refer to the table

accessories and system modifications for reliable system

below for the acceptable vapor tube diameters based on the total

operation. The maximum allowable total equivalent length is 250

length to minimize the cooling capacity loss.

 

 

ft. The maximum vertical separation is 200 ft. when outdoor unit

 

 

 

 

 

 

 

 

 

Acceptable

 

 

Cooling Capacity Loss (%)Total Equivalent Line Length (ft.)

 

 

Unit Nominal Size (Btuh)

Vapor Line

 

 

 

 

 

 

 

 

 

 

 

Standard Application

 

 

Long Line Application Requires Accessories

 

Diameters

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(In. OD)

25

50

80

80+

100

125

150

175

200

225

250

 

 

 

 

 

 

 

 

 

 

 

 

 

18000

1/2

1

2

3

3

4

6

7

8

9

10

12

1---Stage Puron HP

5/8

0

0

1

1

1

1

2

2

3

3

3

24000

5/8

0

1

1

1

2

3

3

4

4

5

6

1---Stage Puron HP

3/4

0

0

0

0

0

1

1

1

1

1

2

30000

5/8

1

2

3

3

3

4

5

6

7

8

9

3/4

0

0

1

1

1

1

2

2

2

3

3

1---Stage Puron HP

 

7/8

0

0

0

0

0

1

1

1

1

1

1

36000

5/8

1

2

4

4

5

6

7

9

10

11

13

3/4

0

0

1

1

1

2

2

3

3

4

4

1---Stage Puron HP

 

7/8

0

0

0

0

0

1

1

1

1

2

2

42000

3/4

0

1

2

2

2

3

4

4

5

6

6

1---Stage Puron HP

7/8

0

0

1

1

1

1

2

2

2

3

3

48000

3/4

0

1

2

2

3

4

5

5

6

7

8

1---Stage Puron HP

7/8

0

0

1

1

1

2

2

2

3

3

4

60000

3/4

1

2

4

4

5

6

7

9

10

11

12

7/8

0

1

2

2

2

3

4

4

5

5

6

1---Stage Puron HP

 

1 1/8

0

0

0

0

1

1

1

1

1

1

2

Standard Length = 80 ft. or less total equivalent length

Applications in this area are long line. Accessories are required as shown recommended on Long Line Application Guidelines

Applications in this area may have height restrictions that limit allowable total equivalent length, when outdoor unit is below indoor unit See Long Line Application Guidelines

213A

3

Page 3
Image 3
Bryant 213A warranty Physical Data, Vapor Line Sizing And Cooling Capacity Loss, PURON 1-STAGEHEAT PUMP APPLICATIONS