286A / 288A

Table 1 – Refrigerant Connections and Recommended Liquid and Vapor Tube Diameters (in.)

Information is Specific to 286A and 288A Models

 

LIQUID

 

RATED VAPOR*

UNIT SIZE

 

 

 

 

 

Connection

 

Tube

Connection

Tube

 

Diameter

 

Diameter

Diameter

Diameter

 

 

 

 

 

 

286A024

3/8

 

3/8

5/8

5/8

 

 

 

 

 

 

286A036

3/8

 

3/8

3/4

3/4

 

 

 

 

 

 

286A048

3/8

 

3/8

7/8

7/8

 

 

 

 

 

 

286A060

3/8

 

3/8

7/8

1-1/8

 

 

 

 

 

 

 

 

 

 

 

 

288A024

3/8

 

3/8

3/4

3/4

288A036

3/8

 

3/8

3/4

3/4

288A048

3/8

 

3/8

7/8

7/8

288A060

3/8

 

3/8

7/8

1-1/8

* Units are rated with 25 ft. (7.6 m) of lineset. See Product Data sheet for performance data when using different size and length linesets.

Notes:

1. Do not apply capillary tube or the fixed orifice indoor coils to these units.

2For Tubing Set lengths between 80 and 200 ft. (24.38 and 60.96 m) horizontal or 20 ft. (6.10 m) vertical differential (250 ft./76.2 m Total Equivalent Length), refer to the Residential Piping and Long Line Guideline for Air Conditioners and Heat Pumps using Puron® Refrigerant.

Table 2 – Accessory Usage

 

REQUIRED FOR LOW---AMBIENT

REQUIRED FOR LONG LINE

REQUIRED FOR SEA COAST

ACCESSORY

COOLING APPLICATIONS

APPLICATIONS

APPLICATIONS*

 

(Below 55°F/12.8_C)

(Within 2 miles/3.22 km)

 

 

Crankcase Heater

Standard

Standard

Standard

 

Standard with Evolutiont Control

 

 

Evaporator Freeze Protection

(Low Ambient not allowed with

No

No

 

non ---communicating thermostat)

 

 

 

Standard with Evolution Control

 

 

Winter Start Control

(Low Ambient not allowed with non ---

No

No

 

communicating thermostat)

 

 

Compressor Start Assist Capacitor

Standard on 286A models.

Standard on 286A models.

Standard on 286A models

and Relay}

Not required for 288A

Not required for 288A

Not required for 288A

 

Standard with Evolution Control

 

 

Low---Ambient Control

(Low ambient not allowed with non ---

No

No

 

communicating thermostat)

 

 

Support Feet

Recommended

No

Recommended

Liquid---Line Solenoid Valve

No

Yes

No

Puron Refrigerant Balance Port

Yes{

Yes{

Yes{

Hard---Shut Off TXV

 

 

 

*For tubing set lengths between 80 and 200 ft. (24.38 and 60.96 m) horizontal or 20 ft. (6.10 m) vertical differential (total equivalent length), refer to the Residential Piping and Long Line Guideline for Air Conditioners and Heat Pumps using Puron® Refrigerant.

{Required on all indoor units. Standard on all new Puron refrigerant fan coils and furnace coils. } Information is specific to 286A and 288A models.

ISO 9001:2000

the environmentally sound refrigerant

REGISTERED

This product has been designed and manufactured to meet Energy Star® criteria for energy efficiency when matched with appropriate coil components. However, proper refrigerant charge and proper air flow are critical to achieve rated capacity and efficiency. Installation of this product should follow all manufacturing refrigerant

charging and air flow instructions. Failure to confirm proper charge and air flow may reduce energy efficiency and shorten equipment life.

Ready for use in a Hybrid Heatr Duel Fuel system.

4

Page 4
Image 4
Bryant 286A instruction manual Accessory Usage, Liquid Rated Vapor Unit Size