Bryant 3163 service manual Specifications, Refrigerator Will Not Operate on AC

Models: 3163

1 29
Download 29 pages 20.72 Kb
Page 11
Image 11
Refrigerator Will Not Operate on AC

Refrigerator Will Not Operate on AC

Is selector

switch in the AC position?

NO

Set selector switch to AC and start refrigerator.

YES

 

Is thermostat

 

 

set at mid-range

 

 

 

or higher?

 

 

 

NO

Set thermostat to mid-range or higher and start refrigerator.

YES

Is circuit breaker

or fuse blown? (AC source to refrigerator)

YES

Reset circuit

breaker/replace

fuse & start refrigerator.

NO

Is refrigerator’s

AC cord

connected to receptacle?

NO

Connect AC

cord into

receptacle &

start refrigerator.

YES

Are there

NO

loose wire

 

connections?

 

YES

 

Repair

 

loose wire

 

connections.

 

YES

Is AC voltage

YES

 

at output of

 

 

selector switch?

 

 

NO

 

 

Replace

 

 

selector switch

 

 

and start

 

 

refrigerator.

 

 

Is AC voltage

YES

 

at input of

 

 

thermostat?

 

Is AC voltage

 

YES

at input of

 

 

 

 

selector switch?

 

 

 

 

 

NO

Correct AC

source to

selector switch.

Is AC voltage

YES

at output of

 

 

thermostat?

 

 

 

Is AC voltage

to output of fuse?

NO

Replace 3 amp fuse and start refrigerator.

Is AC voltage

at input of

heater?

(Black wires)

YES

YES

Is AC voltage

at input of fuse?

NO

Correct AC

source to

fuse.

Replace

AC Heater.

YES

Is AC voltage

at terminal

block?

NO

Correct power

source to

terminal block.

 

NO

 

 

NO

 

 

 

 

 

 

 

 

 

Correct AC

 

Replace

source to input

 

thermostat and

of thermostat.

 

start refrigerator.

 

 

 

 

 

NO

Correct AC

source to

heater.

Specifications

AC Voltage: 108 - 132 VAC

Current Draw: 1.3 - 1.4 amps

Heater Resistance: 81.7 - 90.3 ohms

10

Page 11
Image 11
Bryant 3163 service manual Specifications, Refrigerator Will Not Operate on AC