Bryant 3163 service manual Refrigerator Will Not Operate on DC Electric, Specifications

Models: 3163

1 29
Download 29 pages 20.72 Kb
Page 13
Image 13
Refrigerator Will Not Operate on DC Electric

Refrigerator Will Not Operate on DC Electric

Is selector switch set to DC?

NO

Set selector switch to DC and start refrigerator.

YES

Is circuit breaker

NO

tripped or fuse

 

blown? (DC

 

to refrigerator)

 

 

 

 

 

YES

 

 

 

 

 

 

Reset circuit

 

breaker/replace

 

fuse & start

 

refrigerator.

 

 

 

 

Replace

YES

 

DC heater.

 

 

 

Are there

NO

loose wire

 

 

connections?

 

 

 

YES

Repair loose connections and start refrigerator.

Is 12 VDC at

YES

output of DC Voltage: 11.5 - 15.4 VDC selector switch?

Is 12 VDC at

YES

 

terminal block?

 

 

 

NO

Correct DC to

terminal block & start refrigerator 11.5 VDC min..

Is 12 VDC at

YES

input of Current Draw: 11.7 - 13.6 amps selector switch?

Is 12 VDC to

input of 20 amp fuse?

NO

Correct DC

source to fuse.

Is 12 VDC at

output of fuse?

YES

 

NO

 

 

NO

 

 

NO

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Replace

 

Correct DC

 

Replace 20

selector switch

 

 

 

source

 

& start

 

 

amp fuse.

 

to switch.

 

refrigerator.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Specifications

DC Voltage: 11.5 - 15.4 VDC

Current Draw: 11.7 - 13.6 amps

Heater Resistance: .95 - 1.05 ohms

12

Page 13
Image 13
Bryant 3163 service manual Refrigerator Will Not Operate on DC Electric, Specifications, DC Voltage 11.5 - 15.4 VDC