Bryant 3163 Lighting and Start-Up Instructions, AC Operation, DC Operation, Gas Operation

Models: 3163

1 29
Download 29 pages 20.72 Kb
Page 7
Image 7
Lighting and Start-Up Instructions

Lighting and Start-Up Instructions

A

B

C

E

G

 

 

 

 

D

F

Figure 8

The Lighting and Start-Up Instructions are located on the top portion of the interior door liner.

Refer to Figure 8 for location of the operating controls. Notice: When warm humid weather conditions are ob- served, operate the refrigerator on either AC or DC electric for a minimum of five (5) minutes before attempting to follow the Start-Up Instruc-

tions for Gas operation.

AC Operation

1.Press mode selection button (C).

2.Set the thermostat (B) to the coldest (maximum) setting. Allow to operate at maximum setting for 6 to 8 hours before setting to mid range.

DC Operation

1.Press mode selection button (D). There is no need to set thermostat to any setting. The DC operation is a continuous run (no thermostat control) mode.

3.Push and hold the safety valve button (A) until the indicator lamp (G) glows steady. Continue to hold the safety valve button in for 15 seconds and then release. The indicator lamp should remain a steady glow. If the lamp turns off, repeat this step.

Notice: On initial start-up, it may take longer for the burner to light because of air being purged from the gas supply line.

tions for Gas operation.AC Operation WARNING

Do not hold gas valve in more than 30 seconds. If the flame is not indicated within this time, press selector switch (F), wait 2 minutes, and retry. Continuing to hold the gas valve in will cause gas to build up in the burner area and can result in an explosion which can cause property damage or severe personal injury.

1. Set thermostat to desired temperature setting.

Gas Operation

1.Set thermostat (B) to the start setting.

2.Press mode selector button (E). Ignition spark will be present at the burner.

Shut-Down: All Modes

Press mode selector button (F). This will interrupt all AC and DC power and stop operation of the refrigerator.

6

Page 7
Image 7
Bryant 3163 Lighting and Start-Up Instructions, AC Operation, DC Operation, Gas Operation, Shut-Down All Modes