Rialta

1.Turn off the gas supply at the main tank.

2.Turn the refrigerator’s mode selector to "OFF".

3.Remove the refrigerator’s system cover located on the left front of the refrigerator by removing 5 retaining screws.

4.Remove 5 retaining screws securing the refrig- erator to the enclosure.

5.Remove the drawer directly above the refrigerator.

6.Turn the manual shut-off valve located on top of the refrigerator to "OFF". See Figure 12.

7.Disconnect the vehicle’s 12 volt DC supply wires from the refrigerator’s terminal block.

8.Disconnect the LP gas supply line from the refrig- erator’s manual shut-off valve. See Figure 12. CAUTION: To prevent gas leaks and damage to

the gas supply lines and fittings, use two wrenches when connect- ing or disconnecting gas fittings.

9.Disconnect the refrigerator’s AC power cord from the wall receptacle.

10.Open the cabinet door to the left of the refrigera- tor. Remove the access panel at the rear of the cabinet. This will allow access to the refrigerator’s vent-air intake and exhaust piping.

Retaining

Intake Pipe

 

Washer

 

Exhaust Pipe

(Isolated)

Figure 13 - Vent Terminal Housing

11.Remove the phillips head screw and retaining washer which secure the vent-air exhaust and intake flexible vent piping to the vent terminal housing. See Figure 13.

12.Remove both the intake and exhaust vent piping from the vent terminal housing. Care must be taken not to damage the "O" ring seals when removing the piping.

13.Remove right dinette assembly cover panel to access the refrigerator retaining bracket. Refer- ence "Right Dinette Assembly Cover Panel Re- moval" in the Interior Section.

14.Loosen and remove the refrigerator’s retaining screws at rear base of the refrigerator.

15.Position the flexible vent-air intake and exhaust piping to remove the refrigerator from its enclosure.

16.To re-install the refrigerator, reverse the removal procedure.

17.After connecting the vehicle’s gas supply line to the refrigerator’s manual shut-off valve, turn the valve on. Use a manometer and verify that the input gas pressure is at 11" W.C..

18.Turn off the gas supply at the manual shut-off valve. Observe the manometer and verify that the gas pressure is maintained. If not, locate the source of the leak, correct it, and re-test the unit.

19.Apply leak test solution to all gas fittings and verify that there are no leaks. Do not test for gas leaks with an open flame.

21

Page 22
Image 22
Bryant 3163 service manual Rialta

3163 specifications

Bryant 3163 is an advanced heating, ventilation, and air conditioning (HVAC) system that embodies the latest in HVAC technology and efficiency. Designed to meet the needs of modern homeowners, the Bryant 3163 offers a perfect blend of comfort, reliability, and energy savings.

One of the standout features of Bryant 3163 is its state-of-the-art variable-speed compressor. This technology allows the unit to adjust its output based on the specific demands of the environment, providing optimal comfort while minimizing energy consumption. Instead of running at a single, fixed speed like traditional systems, the variable-speed compressor can operate at different levels, ensuring a consistent and comfortable temperature throughout the home.

In addition to its impressive compressor, the Bryant 3163 is equipped with innovative multi-zone capabilities. This system allows homeowners to create separate climate zones within their homes, ensuring individualized comfort for different rooms or areas. This is particularly beneficial for larger homes where temperature preferences can vary widely between family members or activities in different areas.

The system also boasts an advanced air filtration system, which helps improve indoor air quality by capturing allergens, dust, and other airborne particles. The high-efficiency filters not only promote better health but also contribute to the overall efficiency of the HVAC system. Cleaner air means less strain on the system, leading to lower energy bills and an extended lifespan of the unit.

The Bryant 3163 incorporates smart technology, allowing homeowners to control their HVAC system remotely through smartphones or tablets. This feature enhances convenience, enabling users to adjust settings, monitor energy usage, and schedule maintenance with ease.

With a strong focus on energy efficiency, the Bryant 3163 meets stringent energy performance standards, qualifying for various efficiency rebates and incentives. Its quiet operation is another highlight, making it an ideal choice for residential environments where noise reduction is a priority.

In summary, the Bryant 3163 is a cutting-edge HVAC solution that excels in efficiency, comfort, and technology. With its variable-speed compressor, multi-zone capabilities, advanced air filtration, smart technology integration, and emphasis on energy savings, Bryant 3163 stands out as an excellent choice for homeowners seeking dependable climate control that prioritizes both comfort and efficiency.