TABLE 9ÐMODEL 340MAV ORIFICE SIZE AND MANIFOLD PRESSURE FOR CORRECT INPUT FOR USE WITH 140 SIZE FURNACES ONLY

(TABULATED DATA BASED ON 23,000 BTUH PER BURNER, DERATED 2% FOR EACH 1000 FT ABOVE SEA LEVEL)

 

ALTITUDE

AVG GAS

 

 

 

 

 

SPECIFIC GRAVITY OF NATURAL GAS

 

 

 

 

 

HEAT VALUE

 

0.58

 

0.60

 

0.62

0.64

 

0.66

 

 

RANGE

 

 

 

 

 

 

(FT)

AT ALTITUDE

Orifice

 

Manifold

Orifice

 

Manifold

Orifice

 

Manifold

Orifice

 

Manifold

Orifice

 

Manifold

 

 

(BTU/CU FT)

 

 

 

 

 

 

 

 

No.

 

Pressure

No.

 

Pressure

No.

 

Pressure

No.

 

Pressure

No.

 

Pressure

 

 

 

850

41

 

3.6

41

 

3.7

41

 

3.8

40

 

3.6

40

 

3.8

 

 

 

875

42

 

3.8

41

 

3.5

41

 

3.6

41

 

3.7

41

 

3.8

Canada

 

 

900

42

 

3.5

42

 

3.7

42

 

3.8

41

 

3.5

41

 

3.6

 

0

925

42

 

3.4

42

 

3.5

42

 

3.6

42

 

3.7

42

 

3.8

 

 

950

42

 

3.2

42

 

3.3

42

 

3.4

42

 

3.5

42

 

3.6

and

 

to

975

43

 

3.7

43

 

3.8

42

 

3.2

42

 

3.3

42

 

3.4

 

 

1000

43

 

3.5

43

 

3.6

43

 

3.7

42

 

3.2

42

 

3.3

U.S.A.

 

 

 

 

 

 

 

 

2000

1025

43

 

3.3

43

 

3.4

43

 

3.6

43

 

3.7

43

 

3.8

 

 

1050

43

 

3.2

43

 

3.3

43

 

3.4

43

 

3.5

43

 

3.6

 

 

 

 

 

 

 

 

 

 

 

1075

44

 

3.5

44

 

3.6

43

 

3.2

43

 

3.3

43

 

3.4

 

 

 

1100

44

 

3.3

44

 

3.4

44

 

3.5

43

 

3.2

43

 

3.3

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ALTITUDE

AVG GAS

 

 

 

 

 

SPECIFIC GRAVITY OF NATURAL GAS

 

 

 

 

 

HEAT VALUE

 

0.58

 

0.60

 

0.62

0.64

 

0.66

 

 

RANGE

 

 

 

 

 

 

(FT)

AT ALTITUDE

Orifice

 

Manifold

Orifice

 

Manifold

Orifice

 

Manifold

Orifice

 

Manifold

Orifice

 

Manifold

 

 

(BTU/CU FT)

 

 

 

 

 

 

 

 

No.

 

Pressure

No.

 

Pressure

No.

 

Pressure

No.

 

Pressure

No.

 

Pressure

 

 

U.S.A.

775

41

 

3.7

41

 

3.8

40

 

3.6

40

 

3.7

39

 

3.6

 

 

Altitudes

800

42

 

3.8

41

 

3.6

41

 

3.7

41

 

3.8

40

 

3.6

Canada

 

2001

825

42

 

3.6

42

 

3.7

41

 

3.5

41

 

3.6

41

 

3.7

 

to

850

42

 

3.4

42

 

3.5

42

 

3.6

42

 

3.7

41

 

3.5

 

3000

875

42

 

3.2

42

 

3.3

42

 

3.4

42

 

3.5

42

 

3.6

and

 

or

900

43

 

3.7

43

 

3.8

42

 

3.2

42

 

3.3

42

 

3.4

 

Canada

925

43

 

3.5

43

 

3.6

43

 

3.7

42

 

3.2

42

 

3.3

U.S.A.

 

 

 

 

 

 

 

Altitudes

950

43

 

3.3

43

 

3.4

43

 

3.5

43

 

3.7

43

 

3.8

 

2001

975

43

 

3.1

43

 

3.3

43

 

3.4

43

 

3.5

43

 

3.6

 

 

 

 

 

 

 

 

 

to

1000

43

 

3.0

43

 

3.1

43

 

3.2

43

 

3.3

43

 

3.4

 

 

4500

1025

43

 

2.8

43

 

2.9

43

 

3.0

43

 

3.1

43

 

3.2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ALTITUDE

AVG GAS

 

 

 

 

 

SPECIFIC GRAVITY OF NATURAL GAS

 

 

 

 

 

HEAT VALUE

 

0.58

 

0.60

 

0.62

0.64

 

0.66

 

 

RANGE

 

 

 

 

 

 

(FT)

AT ALTITUDE

Orifice

 

Manifold

Orifice

 

Manifold

Orifice

 

Manifold

Orifice

 

Manifold

Orifice

 

Manifold

 

 

(BTU/CU FT)

 

 

 

 

 

 

 

 

No.

 

Pressure

No.

 

Pressure

No.

 

Pressure

No.

 

Pressure

No.

 

Pressure

 

 

 

750

41

 

3.6

41

 

3.8

40

 

3.6

40

 

3.7

40

 

3.8

 

 

 

775

42

 

3.8

41

 

3.5

41

 

3.6

41

 

3.7

40

 

3.6

 

 

 

800

42

 

3.5

42

 

3.7

42

 

3.8

41

 

3.5

41

 

3.6

Only

 

3001

825

42

 

3.3

42

 

3.4

42

 

3.6

42

 

3.7

42

 

3.8

 

 

850

43

 

3.8

42

 

3.2

42

 

3.4

42

 

3.5

42

 

3.6

U.S.A.

 

to

875

43

 

3.6

43

 

3.7

42

 

3.2

42

 

3.3

42

 

3.4

 

 

900

43

 

3.4

43

 

3.5

43

 

3.6

43

 

3.8

42

 

3.2

 

4000

925

43

 

3.2

43

 

3.3

43

 

3.5

43

 

3.6

43

 

3.7

 

 

 

 

 

 

 

 

 

 

950

43

 

3.1

43

 

3.2

43

 

3.3

43

 

3.4

43

 

3.5

 

 

 

975

43

 

2.9

43

 

3.0

43

 

3.1

43

 

3.2

43

 

3.3

 

 

 

1000

43

 

2.8

43

 

2.9

43

 

3.0

43

 

3.0

43

 

3.1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Ð38Ð

Page 38
Image 38
Bryant 340MAV instruction manual Ð38Ð

340MAV specifications

The Bryant 340MAV is a standout model in the Bryant lineup, designed to provide exceptional comfort, efficiency, and performance for residential heating and cooling needs. This unit offers a perfect blend of innovative technology and user-friendly features, making it an ideal choice for homeowners seeking reliability and quality.

One of the defining characteristics of the Bryant 340MAV is its impressive efficiency rating. With a SEER (Seasonal Energy Efficiency Ratio) of up to 18, this model ensures that homeowners can enjoy effective cooling during the summer months while minimizing energy consumption. Similarly, the heating efficiency is notable, with a high AFUE (Annual Fuel Utilization Efficiency) rating. This makes the 340MAV an environmentally friendly option that also promotes cost savings on energy bills.

The 340MAV incorporates advanced technologies that enhance its performance. One such technology is the variable-speed compressor, which allows the system to adjust its output based on the demands of the home. This means that the unit operates more quietly and reduces energy usage by matching the cooling or heating output required. Additionally, the two-stage heating capability provides more consistent temperatures and improved comfort throughout the space.

Operating noise is a crucial factor in residential HVAC systems, and the Bryant 340MAV is designed with this in mind. Engineered for quiet operation, the unit features a sound-dampening design, including an insulated cabinet and a specially designed compressor that minimizes noise levels. Homeowners can enjoy a comfortable indoor climate without the disruptive racket often associated with traditional systems.

Furthermore, the Bryant 340MAV is equipped with a durable all-aluminum coil, which improves heat transfer efficiency while also being resistant to corrosion. This characteristic contributes to the longevity of the unit, ensuring that it can withstand various environmental factors without compromising performance.

Another key feature is the advanced control options that the Bryant 340MAV offers. Integration with smart thermostats allows homeowners to monitor and adjust their HVAC system remotely, ensuring optimal comfort at all times. Additionally, the system is compatible with Bryant's Perfect Air™ filtration system, enhancing indoor air quality by reducing pollutants and allergens.

In summary, the Bryant 340MAV is a high-efficiency heating and cooling solution that brings together cutting-edge technology, quiet operation, and user-friendly features. With its focus on comfort and energy savings, it stands out as a prime choice for homeowners looking to invest in a reliable HVAC system.