TABLE 6ÐMAXIMUM ALLOWABLE PIPE LENGTH (FT) Continued

ALTITUDE

UNIT SIZE

TERMINATION

PIPE DIA

 

 

 

NUMBER OF 90° ELBOWS

 

TYPE

(IN.)*

1

 

2

 

3

4

5

6

 

 

 

 

 

024040

2 Pipe or 2-In.

1-1/2

60

 

55

 

50

45

44

39

 

036040

Concentric

2

70

 

70

 

70

70

70

70

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

024060

2 Pipe or 2-In.

1-1/2

15

 

10

 

5

 

NA

 

NA

NA

 

036060

 

 

 

 

 

 

 

 

 

 

 

 

Concentric

2

64

 

59

 

58

53

52

52

 

048060

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

036080

2 Pipe or 2-In.

2

44

 

39

 

26

21

20

11

 

048080

 

 

 

 

 

 

 

 

 

 

 

4001 to 5000³

Concentric

2-1/2

70

 

70

 

70

70

70

70

060080

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

048100

2 Pipe or 3-In.

2-1/2

31

 

22

 

13

12

 

NA

NA

 

060100

Concentric

3

70

 

70

 

67

62

57

52

 

060120

2 Pipe or 3-In.

3² no disk

53

 

46

 

40

33

26

20

 

Concentric

4² no disk

70

 

70

 

70

70

70

70

 

 

 

 

 

060140

2 Pipe or 3-In.

3² no disk

21

 

17

 

13

9

5

NA

 

Concentric

4² no disk

69

 

64

 

59

54

49

44

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ALTITUDE

UNIT SIZE

TERMINATION

PIPE DIA

 

 

 

NUMBER OF 90° ELBOWS

 

TYPE

(IN.)*

1

 

2

 

3

 

4

 

5

6

 

 

 

 

 

 

 

024040

2 Pipe or 2-In.

1-1/2

57

 

52

 

47

 

42

 

40

35

 

036040

Concentric

2

70

 

70

 

70

 

70

 

70

70

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

024060

2 Pipe or 2-In.

1-1/2

14

 

9

 

NA

 

NA

 

NA

NA

 

036060

 

 

 

 

 

 

 

 

 

 

 

 

Concentric

2

60

 

55

 

54

 

49

 

48

47

 

048060

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

036080

2 Pipe or 2-In.

2

41

 

36

 

23

 

18

 

17

8

 

048080

 

 

 

 

 

 

 

 

 

 

 

5001 to 6000³

Concentric

2-1/2

70

 

70

 

70

 

70

 

70

70

060080

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

048100

2 Pipe or 3-In.

2-1/2

29

 

21

 

12

 

11

 

NA

NA

 

060100

Concentric

3

70

 

67

 

62

 

57

 

52

47

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

060120

2 Pipe or 3-In.

3² no disk

42

 

35

 

29

 

22

 

15

9

 

Concentric

4² no disk

70

 

70

 

70

 

70

 

70

70

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

060140

2 Pipe or 3-In.

3² no disk

12

 

8

 

NA

 

NA

 

NA

NA

 

Concentric

4² no disk

42

 

37

 

32

 

27

 

22

17

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ALTITUDE

UNIT SIZE

TERMINATION

PIPE DIA

 

 

 

NUMBER OF 90° ELBOWS

 

TYPE

(IN.)*

1

 

2

 

3

 

4

 

5

6

 

 

 

 

 

 

 

024040

2 Pipe or 2-In.

1-1/2

53

 

48

 

43

 

38

 

37

32

 

036040

Concentric

2

70

 

70

 

68

 

67

 

66

64

 

024060

2 Pipe or 2-In.

1-1/2

13

 

8

 

NA

 

NA

 

NA

NA

 

036060

 

 

 

 

 

 

 

 

 

 

 

 

Concentric

2

57

 

52

 

50

 

45

 

44

43

 

048060

 

 

 

 

 

 

 

 

 

 

 

036080

2 Pipe or 2-In.

2

38

 

33

 

21

 

16

 

15

6

 

048080

 

 

 

 

 

 

 

 

 

 

 

6001 to 7000³

Concentric

2-1/2

70

 

70

 

68

 

67

 

66

64

060080

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

048100

2 Pipe or 3-In.

2-1/2

27

 

19

 

10

 

9

 

NA

NA

 

060100

Concentric

3

68

 

63

 

58

 

53

 

48

43

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

060120

2 Pipe or 3-In.

3² no disk

31

 

24

 

18

 

11

 

NA

NA

 

Concentric

4² no disk

70

 

70

 

70

 

70

 

67

62

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

060140

2 Pipe or 3-In.

4² no disk

17

 

12

 

7

 

NA

 

NA

NA

 

Concentric

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ALTITUDE

UNIT SIZE

TERMINATION

PIPE DIA

 

 

 

NUMBER OF 90° ELBOWS

 

TYPE

(IN.)*

1

 

2

 

3

 

4

 

5

6

 

 

 

 

 

 

 

024040

2 Pipe or 2-In.

1-1/2

49

 

44

 

39

 

34

 

33

28

 

036040

Concentric

2

66

 

65

 

63

 

62

 

60

59

 

024060

2 Pipe or 2-In.

1-1/2

12

 

7

 

NA

 

NA

 

NA

NA

 

036060

 

 

 

 

 

 

 

 

 

 

 

 

Concentric

2

53

 

48

 

46

 

41

 

40

38

 

048060

 

 

 

 

 

 

 

 

 

 

 

036080

2 Pipe or 2-In.

2

36

 

31

 

19

 

14

 

12

NA

7001 to 8000³

048080

 

 

 

 

 

 

 

 

 

 

 

Concentric

2-1/2

66

 

65

 

63

 

62

 

60

59

 

060080

 

 

 

 

 

 

048100

2 Pipe or 3 In.

2-1/2

25

 

17

 

8

 

7

 

NA

NA

 

060100

Concentric

3

63

 

58

 

53

 

48

 

43

38

 

060120

2 Pipe or 3-In.

3² no disk

20

 

13

 

7

 

NA

 

NA

NA

 

Concentric

4² no disk

61

 

56

 

51

 

46

 

41

36

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

060140

 

 

 

NA

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

See notes on page 26.

Ð25Ð

Page 25
Image 25
Bryant 340MAV instruction manual Ðmaximum Allowable Pipe Length FT, 4001 to 5000³

340MAV specifications

The Bryant 340MAV is a standout model in the Bryant lineup, designed to provide exceptional comfort, efficiency, and performance for residential heating and cooling needs. This unit offers a perfect blend of innovative technology and user-friendly features, making it an ideal choice for homeowners seeking reliability and quality.

One of the defining characteristics of the Bryant 340MAV is its impressive efficiency rating. With a SEER (Seasonal Energy Efficiency Ratio) of up to 18, this model ensures that homeowners can enjoy effective cooling during the summer months while minimizing energy consumption. Similarly, the heating efficiency is notable, with a high AFUE (Annual Fuel Utilization Efficiency) rating. This makes the 340MAV an environmentally friendly option that also promotes cost savings on energy bills.

The 340MAV incorporates advanced technologies that enhance its performance. One such technology is the variable-speed compressor, which allows the system to adjust its output based on the demands of the home. This means that the unit operates more quietly and reduces energy usage by matching the cooling or heating output required. Additionally, the two-stage heating capability provides more consistent temperatures and improved comfort throughout the space.

Operating noise is a crucial factor in residential HVAC systems, and the Bryant 340MAV is designed with this in mind. Engineered for quiet operation, the unit features a sound-dampening design, including an insulated cabinet and a specially designed compressor that minimizes noise levels. Homeowners can enjoy a comfortable indoor climate without the disruptive racket often associated with traditional systems.

Furthermore, the Bryant 340MAV is equipped with a durable all-aluminum coil, which improves heat transfer efficiency while also being resistant to corrosion. This characteristic contributes to the longevity of the unit, ensuring that it can withstand various environmental factors without compromising performance.

Another key feature is the advanced control options that the Bryant 340MAV offers. Integration with smart thermostats allows homeowners to monitor and adjust their HVAC system remotely, ensuring optimal comfort at all times. Additionally, the system is compatible with Bryant's Perfect Air™ filtration system, enhancing indoor air quality by reducing pollutants and allergens.

In summary, the Bryant 340MAV is a high-efficiency heating and cooling solution that brings together cutting-edge technology, quiet operation, and user-friendly features. With its focus on comfort and energy savings, it stands out as a prime choice for homeowners looking to invest in a reliable HVAC system.