SPECIFICATIONS
UNIT |
|
|
| |||||
Operating Weight (Lb) |
| 291 |
| 291 |
| 291 | 291 | |
|
|
|
|
|
|
|
|
|
ELECTRICAL |
|
|
|
|
|
|
| |
Unit VoltsÐHertzÐPhase |
| 208/230Ð60Ð1 |
| |||||
|
|
|
|
|
|
|
| |
Operating Voltage Range* |
|
|
| 187±253 |
| |||
|
|
|
|
|
|
|
|
|
CompressorÐ | Rated Load Amps | 13.5 |
| 14.7 |
| 15.4 | 18.6 | |
|
|
|
|
|
|
|
|
|
|
| Locked Rotor Amps | 61.0 |
| 72.5 |
| 83.0 | 105.0 |
|
|
|
|
|
|
| ||
Condenser Fan MotorÐFull Load Amps | 0.75 |
| 0.75 |
| 1.10 | 1.10 | ||
|
|
|
|
|
|
| ||
Minimum Unit Ampacity for Wire Sizing | TBD |
| TBD |
| TBD | TBD | ||
|
|
|
|
|
|
| ||
Minimum Wire Size (60°C Copper) (AWG)² | TBD |
| TBD |
| TBD | TBD | ||
|
|
|
|
|
|
| ||
Minimum Wire Size (75°C Copper) (AWG)² | TBD |
| TBD |
| TBD | TBD | ||
Maximum Wire Length (60°C) (Ft)³ | TBD |
| TBD |
| TBD | TBD | ||
Maximum Wire Length (75°C) (Ft)³ | TBD |
| TBD |
| TBD | TBD | ||
Maximum Branch Circuit Fuse Size** | TBD |
| TBD |
| TBD | TBD | ||
COMPRESSOR AND REFRIGERANT |
|
|
|
|
|
| ||
CompressorÐ | Manufacturer |
|
|
| Copeland |
| ||
|
| Type |
|
|
|
| Scroll |
|
RefrigerantÐ | Type |
|
|
|
| |||
|
| Amount (Lb)²² | 9.88 |
| 10.25 |
| 10.25 | 10.50 |
OUTDOOR COIL & FAN |
|
|
|
|
|
| ||
Coil Face Area (Sq Ft) |
| 18.25 |
| 18.25 |
| 18.25 | 18.25 | |
Fins per In.ÐRowsÐCircuits | 20Ð2Ð4 |
| 20Ð2Ð4 |
| 20Ð2Ð4 | 20Ð2Ð4 | ||
Fan Motor HP and RPM | 1/8 and 825 |
| 1/8 and 825 |
| 1/5 and 825 | 1/5 and 825 | ||
Rated Airflow (CFM) |
| 2400 |
| 2400 |
| 2800 | 2800 | |
OPTIONAL EQUIPMENT |
|
|
|
|
|
| ||
Support FeetÐ4 In. (4) |
|
|
| KSASF0101AAA |
| |||
Coastal Filter |
|
|
| KAACF0201MED |
| |||
|
|
|
|
|
|
| ||
|
|
| KAATD0101TDR |
| ||||
|
|
|
|
|
| |||
Cycle |
|
| KSACY0101AAA |
| ||||
|
|
|
|
|
| |||
Start AssistÐCapacitor/Relay Type |
|
| KSAHS1501AAA |
| ||||
|
|
|
|
|
|
| ||
TXV (Hard Shutoff) |
| KSATX0201HSZ |
| KSATX0301HSZ | ||||
|
|
|
|
|
| |||
Filter Drier (Suction Line) |
| KH45LG140 (RCD) | KH45LG141 (RCD) | |||||
|
|
|
|
|
| |||
Evaporator Freeze Thermostat³³ |
|
| KAAFT0101AAA |
| ||||
|
|
|
|
|
| |||
|
| KAALS0201LLS |
| |||||
|
|
|
|
|
|
| ||
Winter Start Control |
|
|
| KAAWS0101AAA |
| |||
|
|
|
|
|
| |||
|
| KSALA0301410 |
| |||||
|
|
|
|
|
|
| ||
|
|
|
| |||||
|
|
|
|
|
| |||
MotorMaster® Control*** |
|
| 32LT660004 (RCD) |
| ||||
|
|
|
|
|
|
|
| |
Ball Bearing Fan Motor |
|
|
|
| HC38GE230 |
| ||
|
|
|
|
|
|
| ||
ThermostatÐAuto Changeover, |
|
|
| |||||
°F/°C, |
|
|
| |||||
|
|
|
|
|
| |||
|
|
|
|
|
|
| ||
ThermostatÐAuto Changeover, |
|
|
| |||||
°F/°C, |
|
|
| |||||
|
|
|
|
|
| |||
Thermidistat™ ControlÐProgrammable Thermostat |
|
|
| |||||
with Humidity Control |
|
|
|
| ||||
|
|
|
|
|
|
| ||
ThermostatÐManual Changeover, |
|
|
| HH07AT212 |
| |||
°F, |
|
|
|
| ||||
|
|
|
|
|
| |||
Outdoor Air Temperature Sensor |
|
| TSTATXXSEN01 |
| ||||
Backplate for |
|
| TSTATXXNBP01 |
| ||||
Backplate for Programmable Thermostat |
|
| TSTATXXPBP01 |
| ||||
Thermostat Conversion Kit (4 to 5 Wire)Ð10 Pack |
|
| TSTATXXCNV10 |
| ||||
|
|
|
|
|
|
|
|
|
* Permissible limits of the voltage range at which unit will operate satisfactorily. Operation outside these limits may result in unit failure.
²If other than uncoated
If wire is applied at ambient greater than 30°C (86°F), consult Table
³Length shown is as measured 1 way along the wire path between the unit and the service panel for a voltage drop not to exceed 2 percent. **
²² The factory refrigerant charge is for 15 ft of interconnecting tubing. For tubing lengths other 15 ft, refer to the
³³ Use with
*** Fan motor with ball bearings required. TBDÐTo Be Determined
NOTE: Copper wire must be used from service disconnect to unit. All motors/compressors contain internal overload protection.
Ð4Ð