Bryant 556A warranty R-410AÐQUICKREFERENCE GUIDE

Models: 556A

1 8
Download 8 pages 52.27 Kb
Page 6
Image 6

R-410AÐQUICK REFERENCE GUIDE

·R-410A refrigerant operates at 50-70 percent higher pressures than R-22. Be sure that servicing equipment and replacement components are designed to operate with R-410A.

·R-410A refrigerant cylinders are rose colored.

·R-410A refrigerant cylinders have a dip tube which allows liquid to flow out of cylinder in upright position.

·Recovery cylinder service pressure rating must be 400 psig, DOT 4BA400 or DOT BW400.

·R-410A systems should be charged with liquid refrigerant. Use a commercial type metering device in the manifold hose.

·Manifold sets should be 700 psig high side and 180 psig low side with 550 psig low-side retard.

·Use hoses with 700 psig service pressure rating.

·Leak detectors should be designed to detect HFC refrigerant.

·R-410A, as with other HFCs, is only compatible with POE oils.

·Vacuum pumps will not remove moisture from oil.

·Do not use liquid-line filter driers with rated working pressures less than 600 psig.

·Do not install a suction-line filter drier in liquid line.

·POE oils absorb moisture rapidly. Do not expose oil to atmosphere.

·POE oils may cause damage to certain plastics and roofing materials.

·Wrap all filter driers and service valves with wet cloth when brazing.

·A liquid-line filter drier is required on every unit.

·Do not use an R-22 TXV.

·If indoor unit is equipped with an R-22 TXV, it must be changed to an R-410A TXV.

·Never open system to atmosphere while it is under a vacuum.

·When system must be opened for service, break vacuum with dry nitrogen prior to opening to atmosphere.

·Always replace filter drier after opening system for service.

·Do not vent R-410A into the atmosphere.

·Do not use capillary tube coils.

·Observe all warnings, cautions, and bold text.

Ð6Ð

Page 6
Image 6
Bryant 556A warranty R-410AÐQUICKREFERENCE GUIDE