ACCESSORY USAGE GUIDELINE
| REQUIRED FOR | REQUIRED FOR | REQUIRED FOR | REQUIRED FOR | |
ACCESSORY | BURIED LINE | SEA COAST | |||
APPLICATIONS | APPLICATIONS* | APPLICATIONS² | APPLICATIONS | ||
| |||||
| (BELOW 55°F) | (OVER 50 FT) | (OVER 3 FT) | (WITHIN 2 MILES) | |
Crankcase Heater | Yes | Yes | Yes | No | |
Evaporator Freeze Thermostat | Yes | No | No | No | |
Winter Start Control | Yes³ | No | No | No | |
Accumulator | No | No | Yes | No | |
Compressor Start Assist | Yes | Yes | Yes | No | |
Capacitor and Relay | |||||
|
|
|
| ||
|
|
|
| ||
MotorMaster® Control, | Yes | No | No | No | |
or | |||||
|
|
|
| ||
|
|
|
| ||
Wind Baffle | See | No | No | No | |
Coastal Filter | No | No | No | Yes | |
Support Feet | Recommended | No | No | Recommended | |
| See |
|
| ||
or | No | Application | Yes | No | |
Hard Shutoff TXV |
| Guideline |
|
| |
Ball Bearing Fan Motor | Yes** | No | No | No | |
|
|
|
|
|
*For tubing line sets between 50 and 175 ft, refer to the Application Guideline and Service Manual for Residential
²For buried line applications, refer to Residential Split System
** Required for
Ð5Ð