CHECK-FLO-RATER® PISTON CHART

 

PISTON*

UNIT SIZE

IDENTIFICATION NO.

018-A, D

52

024-A, D

57

030-A, D

67

036-A, D, E

73

036-B

70

042-A, C

76

042-B

82

048-A, C

88

048-B

84

060-A, E

93

060-B

90

*Piston listed is for any approved coil non-capillary tube combination. Piston is shipped with outdoor unit and must be installed in an approved indoor coil.

RECOMMENDED TUBE DIAMETERS

 

Liquid Tube Diameter (In.)

 

Vapor Tube Diameter (In.)

UNIT

0 to 50 Ft

 

0 to 50 Ft

 

Long-Line Applications*

SIZE

Tube Length

Long-Line Applications*

Tube Length

 

(Maximum Diameter)

018, 024

 

 

5/8

 

3/4

030, 036

3/8

3/8

3/4

 

7/8

042, 048

7/8

 

1-1/8

 

 

 

060

 

 

1-1/8

 

1-1/8

* For tube sets between 50 and 175 ft, consult Residential Split System Long-Line Application Guideline.

SOUND POWER (dBA)

UNIT

SOUND

 

 

OCTAVE BAND CENTER FREQUENCY (Hz)

 

 

SIZE

LEVEL (dBA)

125

250

500

1000

2000

4000

8000

018-A

80

55.5

64.0

68.5

73.0

71.0

66.5

59.5

018-D

80

57.5

64.0

69.5

72.0

71.5

68.0

60.0

024-A

80

59.5

65.0

69.5

74.0

73.0

70.0

62.0

024-D

82

55.5

63.0

68.0

71.0

70.5

67.5

58.5

030-A

80

55.0

62.5

73.5

74.0

71.0

67.5

59.5

030-D

80

54.0

68.5

72.5

73.0

70.5

67.0

61.5

036-A

82

57.0

64.5

73.0

74.0

72.0

73.0

65.5

036-B

82

55.0

64.0

73.0

74.5

72.0

68.5

64.0

036-D

82

56.0

64.5

69.0

75.5

75.0

72.0

69.5

036-E

82

56.5

70.0

73.5

75.5

74.5

71.0

65.0

042-A

82

58.0

69.5

73.0

71.5

69.5

68.0

63.5

042-B

82

59.0

66.5

68.5

75.5

71.5

73.0

65.5

042-C

82

57.0

69.0

72.5

71.5

69.5

68.0

64.0

048-A

82

58.5

72.5

74.0

77.0

72.5

70.0

65.0

048-B

82

57.0

67.5

72.0

73.0

68.5

67.0

60.5

048-C

82

61.0

69.0

70.0

74.0

75.5

74.5

66.5

060-A

82

57.5

68.0

69.0

72.5

70.5

71.0

70.0

060-B

82

57.5

69.5

75.0

76.0

70.5

69.0

63.0

060-E

82

58.0

64.0

70.0

74.0

72.0

71.0

67.0

T

U

C

 

A

 

F

 

U

 

N

 

A

 

M

R

E

R

 

 

 

D

 

 

FIE

 

 

TI

 

 

R

 

E

 

 

C

 

 

 

 

 

Y

 

IT

A

R

 

 

 

 

 

 

N

 

 

 

U

 

 

 

T

 

 

O A

 

 

RI

 

 

AS

 

 

C

AIR

O

C

M

 

P

 

O

L

 

N

 

D

Y

 

I

 

T

I

 

O

N

 

I

 

 

N

G

 

I

W

 

N

 

G

I

 

 

T

 

 

H

A RI

S

E

T

 

 

QUI PMEN

0

 

 

 

1

 

2

 

 

D

 

TANDAR

 

CERTIFICATION APPLIES ONLY

REGISTERED QUALITY SYSTEM

WHEN THE COMPLETE SYSTEM

 

IS LISTED WITH ARI.

 

—3—

Page 3
Image 3
Bryant 561C warranty CHECK-FLO-RATER Piston Chart, Recommended Tube Diameters