Bryant 697C warranty COMBINATION RATINGS* Continued

Models: 697C

1 36
Download 36 pages 52.23 Kb
Page 15
Image 15

COMBINATION RATINGS* Continued

 

 

 

 

 

 

ARI STANDARD RATINGS*

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

UNIT SIZE-

 

 

 

Cooling

 

 

 

 

 

Heating

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Seasonal Efficiency SEER

 

 

 

 

 

SERIES

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

AND

 

 

Factory-

 

Field-Supplied

High-Temp

Low-Temp

Seasonal

SOUND

 

 

Supplied

 

Accessory‡

 

 

 

 

Efficiency

RATING

INDOOR

 

Enhance-

Standard

 

 

 

 

 

 

 

HSPF/HSPF

 

 

 

 

TC

COP

TC

COP

(dBA)

UNIT

TC

ment

Rating

TXV

 

TXV&TDR**

with LSV

 

 

 

COILS + 333(B,J)AV060100 VARIABLE-SPEED FURNACE

 

 

 

 

CC5A/CD5A/CD5BA060

55,500

TDR

11.50

 

61,000

2.84

38,500

2.32

7.20/7.40

 

CD3(A,B)A060

55,500

TDR

11.50

 

61,000

2.84

38,500

2.32

7.20/7.40

 

CC5A/CD5A/CD5BW060

57,000

TDR

12.00

 

61,000

3.04

39,000

2.44

7.80/8.00

 

CE3AA060

57,500

TDR

12.00

 

61,000

3.02

39,000

2.42

7.80/8.00

 

CJ5A/CK5A/CK5BA060

57,500

TDR

12.00

 

61,000

2.94

38,500

2.40

7.50

 

CJ5A/CK5A/CK5BX060

58,500

TDR

12.20

 

61,000

3.12

38,500

2.48

7.80

 

CK3BA060

57,500

TDR

12.00

 

61,000

2.94

38,500

2.40

7.50

060-A

 

 

COILS + 333(B,J)AV060120 VARIABLE-SPEED FURNACE

 

 

 

 

CC5A/CD5A/CD5BA060

55,000

TDR

11.50

 

61,000

2.80

39,000

2.30

7.20/7.40

76

CD3(A,B)A060

55,000

TDR

11.50

 

61,000

2.80

39,000

2.30

7.20/7.40

CC5A/CD5A/CD5BW060

56,500

TDR

12.00

 

61,000

3.02

39,000

2.42

7.50/7.70

 

CE3AA060

57,500

TDR

12.00

 

61,000

3.00

39,000

2.42

7.50/7.70

 

CJ5A/CK5A/CK5BA060

57,500

TDR

11.80

 

61,000

2.96

38,500

2.38

7.50

 

CJ5A/CK5A/CK5BX060

58,000

TDR

12.00

 

61,000

3.10

38,500

2.46

7.80

 

CK3BA060

57,500

TDR

11.80

 

61,000

2.96

38,500

2.38

7.50

 

 

 

COILS + 355MAV060100 VARIABLE-SPEED FURNACE

 

 

 

 

CC5A/CD5A/CD5BA060

55,000

TDR

11.20

 

61,000

2.80

39,500

2.30

7.20/7.40

 

CD3(A,B)A060

55,000

TDR

11.20

 

61,000

2.80

39,500

2.30

7.20/7.40

 

CC5A/CD5A/CD5BW060

56,500

TDR

11.50

 

61,000

3.00

39,500

2.40

7.50/7.70

*Ratings are net values reflecting the effects of circulating fan heat. Supplemental electric heat is not included. Ratings are based on: Cooling Standard: 80°F (27°C) db 67°F (19°C) wb indoor entering air temperature and 95°F (35°C) db air entering outdoor unit. High-Temp Heating Standard: 70°F (21°C) db indoor entering air temperature and 47°F (8°C) db 43°F (6°C) wb air entering outdoor unit. Low-Temp Heating Standard: 70°F (21°C) db indoor entering air temperature and 17°F (–9°C) db 15°F (–10°C) wb air entering outdoor unit.

Outdoor section/indoor section combination tested in accordance with DOE test procedures for heat pumps. Ratings for other combinations are determined under DOE computer simulation procedures.

Requires hard shutoff TXV; based on computer simulation. ** TDR is on all furnaces, except 394HAD.

SEER — Seasonal Energy Efficiency Ratio

LSV — Liquid Solenoid Valve

COP — Coefficient of Performance

TDR Time-Delay Relay

HSPF — Heating Seasonal Performance Factor

TXV — Thermostatic Expansion Valve

TC — Total Capacity (Btuh)

 

—15—

Page 15
Image 15
Bryant 697C warranty COMBINATION RATINGS* Continued