COMBINATION RATINGS* Continued
|
|
|
|
|
| ARI STANDARD RATINGS* |
|
|
| |||
|
|
|
|
|
|
|
|
|
|
|
|
|
UNIT SIZE- |
|
|
| Cooling |
|
|
|
|
| Heating |
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
| Seasonal Efficiency SEER |
|
|
|
|
| |||||
SERIES |
|
|
|
|
|
|
| |||||
|
|
|
|
|
|
|
|
|
|
|
| |
AND |
|
| Factory- |
| Seasonal | |||||||
SOUND |
|
| Supplied |
| Accessory‡ |
|
|
|
| Efficiency | ||
RATING | INDOOR |
| Enhance- | Standard |
|
|
|
|
|
|
| HSPF/HSPF |
|
|
|
| TC | COP | TC | COP | |||||
(dBA) | UNIT | TC | ment | Rating | TXV |
| TXV&TDR** | with LSV | ||||
|
|
| COILS + 333(B,J)AV060100 |
|
|
| ||||||
| CC5A/CD5A/CD5BA060 | 55,500 | TDR | — | 11.50 |
| — | 61,000 | 2.84 | 38,500 | 2.32 | 7.20/7.40 |
| CD3(A,B)A060 | 55,500 | TDR | — | 11.50 |
| — | 61,000 | 2.84 | 38,500 | 2.32 | 7.20/7.40 |
| CC5A/CD5A/CD5BW060 | 57,000 | TDR | — | 12.00 |
| — | 61,000 | 3.04 | 39,000 | 2.44 | 7.80/8.00 |
| CE3AA060 | 57,500 | TDR | — | 12.00 |
| — | 61,000 | 3.02 | 39,000 | 2.42 | 7.80/8.00 |
| CJ5A/CK5A/CK5BA060 | 57,500 | TDR | — | 12.00 |
| — | 61,000 | 2.94 | 38,500 | 2.40 | 7.50 |
| CJ5A/CK5A/CK5BX060 | 58,500 | TDR | — | 12.20 |
| — | 61,000 | 3.12 | 38,500 | 2.48 | 7.80 |
| CK3BA060 | 57,500 | TDR | — | 12.00 |
| — | 61,000 | 2.94 | 38,500 | 2.40 | 7.50 |
|
| COILS + 333(B,J)AV060120 |
|
|
| |||||||
| CC5A/CD5A/CD5BA060 | 55,000 | TDR | — | 11.50 |
| — | 61,000 | 2.80 | 39,000 | 2.30 | 7.20/7.40 |
76 | CD3(A,B)A060 | 55,000 | TDR | — | 11.50 |
| — | 61,000 | 2.80 | 39,000 | 2.30 | 7.20/7.40 |
CC5A/CD5A/CD5BW060 | 56,500 | TDR | — | 12.00 |
| — | 61,000 | 3.02 | 39,000 | 2.42 | 7.50/7.70 | |
| CE3AA060 | 57,500 | TDR | — | 12.00 |
| — | 61,000 | 3.00 | 39,000 | 2.42 | 7.50/7.70 |
| CJ5A/CK5A/CK5BA060 | 57,500 | TDR | — | 11.80 |
| — | 61,000 | 2.96 | 38,500 | 2.38 | 7.50 |
| CJ5A/CK5A/CK5BX060 | 58,000 | TDR | — | 12.00 |
| — | 61,000 | 3.10 | 38,500 | 2.46 | 7.80 |
| CK3BA060 | 57,500 | TDR | — | 11.80 |
| — | 61,000 | 2.96 | 38,500 | 2.38 | 7.50 |
|
|
| COILS + 355MAV060100 |
|
|
| ||||||
| CC5A/CD5A/CD5BA060 | 55,000 | TDR | — | 11.20 |
| — | 61,000 | 2.80 | 39,500 | 2.30 | 7.20/7.40 |
| CD3(A,B)A060 | 55,000 | TDR | — | 11.20 |
| — | 61,000 | 2.80 | 39,500 | 2.30 | 7.20/7.40 |
| CC5A/CD5A/CD5BW060 | 56,500 | TDR | — | 11.50 |
| — | 61,000 | 3.00 | 39,500 | 2.40 | 7.50/7.70 |
*Ratings are net values reflecting the effects of circulating fan heat. Supplemental electric heat is not included. Ratings are based on: Cooling Standard: 80°F (27°C) db 67°F (19°C) wb indoor entering air temperature and 95°F (35°C) db air entering outdoor unit.
†Outdoor section/indoor section combination tested in accordance with DOE test procedures for heat pumps. Ratings for other combinations are determined under DOE computer simulation procedures.
‡Requires hard shutoff TXV; based on computer simulation. ** TDR is on all furnaces, except 394HAD.
SEER — Seasonal Energy Efficiency Ratio | LSV — Liquid Solenoid Valve |
COP — Coefficient of Performance | TDR — |
HSPF — Heating Seasonal Performance Factor | TXV — Thermostatic Expansion Valve |
TC — Total Capacity (Btuh) |
|