Bryant 697C warranty SPECIFICATIONS Continued

Models: 697C

1 36
Download 36 pages 52.23 Kb
Page 5
Image 5

SPECIFICATIONS Continued

UNIT SIZE-SERIES

048-A

 

060-A

 

Operating Weight (Lb)

265

 

327

ELECTRICAL

 

 

 

Unit Volts-Hertz-Phase

 

208/230-60-1

Operating Voltage Range

 

187—253

Unit Ampacity for Wire Sizing

34.0

 

45.0

Min Wire Size (60°C/75°C Copper) (AWG)*

8/10

 

6/8

Maximum Length (60°C/75°C) (Ft)**

91/56

 

116/66

Max. Branch Circuit Fuse Size (Amps)‡

50

 

60

Compressor Rated Load Amps

26.5

 

34.9

Locked Rotor Amps

129.0

 

169.0

Fan Motor HP and RPM

1/8 and 820

 

1/5 and 820

Full Load Amps

1.0

 

1.4

COMPRESSOR AND REFRIGERANT

 

 

 

Compressor

 

Scroll

Refrigerant—Type and Amount (Lb)†

R-22 and 11.88

 

R-22 and 14.88

OUTDOOR COIL AND FAN

 

 

 

Coil Face Area (Sq Ft)

18.18

 

24.89

Rated Airflow (CFM)

2900

 

3600

OPTIONAL EQUIPMENT

 

 

 

Support Feet—4 In. (4)

 

KSASF0101AAA

Snow Stand—18 In.

KHASS0206MPK

 

KHASS0306MPK

Time-Delay Relay

 

KAATD0101TDR

Interface Control‡‡‡

 

KHAIC0101AAA

Service Alarm

 

KHASA0101AAA††

Outdoor Thermostat

 

KHAOT0301FST

Secondary Outdoor Thermostat

 

KHAOT0201SEC

Cycle Protector

 

Standard

Crankcase Heater

 

Standard

Start Assist—PTC

 

KAACS0201PTC

Start Capacitor and Relay

 

KSAHS1601AAA

Sound Hood

 

Standard

Bi-flow TXV Kits (Hard Shutoff)

KHATX1301HSO

 

KHATX1401HSO

Bi-flow TXV Kits (RPB)

 

 

N/A

Low-Pressure Switch

 

Standard

High-Pressure Switch

 

Standard

Evaporator Freeze Thermostat

 

KAAFT0101AAA‡‡

Isolation Relay

 

KHAIR0101AAA‡‡

Liquid Solenoid Valve (LSV)

 

KHALS0101LLS

Filter Drier—Bi-flow

 

P504-8163S (RCD)

Low-Ambient Controller

 

P251-0083 (RCD)

MotorMaster® Control

 

32LT660004***

Ball Bearing Fan Motor

 

HC38GE230 (RCD)

Thermostat, Auto Changeover,

 

 

 

Non-Programmable, °F/°C,

 

 

 

2-Stage Heat, 1-Stage Cool

 

TSTATBHNHP01-A

Thermostat, Auto Changeover,

 

 

 

7-Day Programmable, °F/°C,

 

 

 

2-Stage Heat, 1-Stage Cool

 

TSTATBHPHP01-A

Thermostat, Manual Changeover,

 

 

 

Non-Programmable, °F,

 

 

 

2-Stage Heat, 1-Stage Cool

 

HH07AT214

Thermostat, Auto Changeover,

 

 

 

Non-Programmable, °F/°C,

 

 

 

Dual Fuel Thermostat. Must be used with

 

 

 

Outdoor Sensor (TSTATBBSEN01)

 

TSTATBHPDF01-A†††

Outdoor Sensor

 

TSTATBBSEN01

*If wire is applied at ambient greater than 30°C (86°F), consult Table 310-16 of the NEC (ANSI/NFPA 70). If other than uncoated (non-plated), 60° or 75°C (140° or 167°F) insulation, copper wire (solid wire for 10 AWG and smaller, stranded wire for larger than 10 AWG) is used, consult applicable tables of the NEC (ANSI/NFPA 70). The ampacity of nonmetallic-sheathed cable (NM), trade name ROMEX, shall be that of 60°C (140°F) conductors, per the NEC

(ANSI/NFPA 70) Article 336-30.

The factory refrigerant charge is for 15 ft of interconnecting tubing. For tubing lengths other than 15 ft, see Long-Line Application Guideline for additional refrigerant requirements.

Time-delay fuse or HACR breaker.

**Length shown is as measured 1 way along the wire path between the unit and the service panel for voltage drop not to exceed 2%.

††For indicator light function, thermostat specified must be used and wired according to efficiency service alarm Installation Instructions. ‡‡ Used with low-ambient controller.

***Fan motor with ball bearings required.

†††High-pressure switch must be added if not supplied with the system.

‡‡‡ Outdoor thermostat required. N/A—Not Applicable

—5—

Page 5
Image 5
Bryant 697C warranty SPECIFICATIONS Continued