HEAT PUMP HEATING PERFORMANCE Continued

 

INDOOR

 

 

 

 

 

 

OUTDOOR COIL ENTERING AIR TEMPERATURES °F

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

AIR

 

–3

 

 

7

 

 

17

 

 

27

 

 

37

 

 

47

 

 

57

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Capacity

Total

Capacity

Total

Capacity

Total

Capacity

Total

Capacity

Total

Capacity

Total

Capacity

Total

 

 

 

 

(MBtuh)

Pwr

(MBtuh)

Pwr

(MBtuh)

Pwr

(MBtuh)

Pwr

(MBtuh)

Pwr

(MBtuh)

Pwr

(MBtuh)

Pwr

 

 

EDB

CFM

Total

Int*

Kw†

Total

Int*

Kw†

Total

Int*

Kw†

Total

Int*

Kw†

Total

Int*

Kw†

Total

Int*

Kw†

Total

Int*

Kw†

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

697C048-A Outdoor Section With FK4CNF005 Indoor Section

 

 

 

 

 

 

 

65

1260

21.2

19.5

3.06

25.5

23.4

3.22

30.3

27.6

3.38

35.9

32.7

3.5

41.6

37.9

3.79

48.6

48.6

4.07

56.9

56.9

4.43

 

 

1400

21.4

19.7

3.06

25.7

23.6

3.20

30.5

27.8

3.35

36.2

33.0

3.5

42.0

38.2

3.73

49.1

49.1

3.99

57.4

57.4

4.33

 

 

 

1610

21.6

19.9

3.07

25.9

23.8

3.19

30.8

28.0

3.33

36.6

33.3

3.5

42.4

38.6

3.67

49.6

49.6

3.91

58.1

58.1

4.23

 

 

70

1260

20.8

19.1

3.21

25.3

23.2

3.39

30.0

27.4

3.57

35.6

32.4

3.7

41.2

37.5

4.00

48.1

48.1

4.29

56.1

56.1

4.66

 

 

1400

21.0

19.3

3.20

25.4

23.4

3.37

30.2

27.5

3.54

35.9

32.7

3.7

41.5

37.8

3.94

48.5

48.5

4.20

56.7

56.7

4.56

 

 

 

1610

21.3

19.6

3.21

25.7

23.6

3.37

30.5

27.8

3.51

36.2

33.0

3.6

41.9

38.2

3.87

49.0

49.0

4.12

57.4

57.4

4.45

 

 

75

1260

20.4

18.8

3.36

25.0

23.0

3.57

29.7

27.1

3.76

35.2

32.1

3.9

40.7

37.1

4.22

47.5

47.5

4.53

55.5

55.5

4.91

 

 

1400

20.6

19.0

3.36

25.2

23.2

3.55

29.9

27.3

3.73

35.5

32.3

3.9

41.1

37.4

4.15

47.9

47.9

4.44

56.0

56.0

4.80

 

 

 

1610

20.9

19.2

3.36

25.4

23.4

3.54

30.2

27.5

3.70

35.8

32.6

3.9

41.5

37.7

4.09

48.4

48.4

4.35

56.6

56.6

4.69

 

Multipliers for Determining the Performance With Other Indoor Sections

 

Indoor

 

 

Heating

Indoor

 

 

Heating

 

 

 

 

 

 

 

 

 

 

 

 

Section

Size

Capacity

 

Power

Section

Size

Capacity

 

Power

 

 

 

 

 

 

 

 

 

 

 

 

 

 

F(A,B)4AN(F,B,C)

048

1.02

 

1.10

CJ5A/CK5A/CK5BA

060

0.98

 

1.08

 

 

 

060

1.03

 

1.08

CJ5A/CK5A/CK5BW

048

0.98

 

1.09

 

 

FB4ANB

070

1.03

 

1.03

CJ5A/CK5A/CK5BX

060

1.00

 

1.02

 

 

FC4BN(F,B)

048

1.02

 

1.10

CK3BA

048

0.98

 

1.09

 

 

 

060

1.03

 

1.08

 

060

0.98

 

1.08

 

 

FC4BNB

054

1.03

 

1.01

COILS + 333(B,J)AV060120 VARIABLE-SPEED FURNACE

 

 

 

070

1.03

 

1.03

CC5A/CD5A/CD5BA

060

0.98

 

1.10

 

 

FG3AAA

048

1.01

 

1.12

CC5A/CD5A/CD5BW

060

1.00

 

1.05

 

 

 

060

1.01

 

1.10

CD3(A,B)A

060

0.98

 

1.10

 

 

FK4BNB

006

1.01

 

0.96

CE3AA

060

1.00

 

1.05

 

 

FK4CNB

006

1.01

 

0.97

CJ5A/CK5A/CK5BA

060

0.98

 

1.08

 

 

FK4CNF

005

1.00

 

1.00

CJ5A/CK5A/CK5BW

048

0.98

 

1.10

 

 

CC5A/CD5A/CD5BA

060

1.00

 

1.13

CJ5A/CK5A/CK5BX

060

0.99

 

1.05

 

 

CC5A/CD5A/CD5BC

048

0.99

 

1.16

CK3BA

048

0.98

 

1.10

 

 

CC5A/CD5A/CD5BW

048

1.00

 

1.12

 

060

0.98

 

1.08

 

 

 

060

1.01

 

1.08

COILS + 355MAV042040 VARIABLE-SPEED FURNACE

 

 

CD3(A,B)A

048

1.00

 

1.12

CC5A/CD5A/CD5BA

060

1.00

 

1.15

 

 

 

060

1.00

 

1.13

CC5A/CD5A/CD5BW

060

1.01

 

1.09

 

 

CD5A/CD5BA

048

1.00

 

1.12

CD3(A,B)A

060

1.00

 

1.15

 

 

CE3AA

048

1.01

 

1.12

COILS + 355MAV042060 VARIABLE-SPEED FURNACE

 

 

 

060

1.01

 

1.08

CC5A/CD5A/CD5BA

060

1.00

 

1.14

 

 

CF5AA

048

1.00

 

1.13

CC5A/CD5A/CD5BW

060

1.01

 

1.09

 

 

CJ5A/CK5A/CK5BA

048

0.99

 

1.14

CD3(A,B)A

060

1.00

 

1.14

 

 

 

060

1.00

 

1.14

COILS + 355MAV042080 VARIABLE-SPEED FURNACE

 

 

CJ5A/CK5A/CK5BN

060

1.00

 

1.14

CC5A/CD5A/CD5BA

060

1.00

 

1.13

 

 

CJ5A/CK5A/CK5BW

048

0.99

 

1.14

CC5A/CD5A/CD5BW

060

1.01

 

1.08

 

 

CJ5A/CK5A/CK5BX

060

1.00

 

1.10

CD3(A,B)A

060

1.00

 

1.13

 

 

CK3BA

048

0.99

 

1.14

COILS + 355MAV060100 VARIABLE-SPEED FURNACE

 

 

 

060

1.00

 

1.14

CC5A/CD5A/CD5BA

060

1.00

 

1.13

 

 

COILS + 333(B,J)AV048080 VARIABLE-SPEED FURNACE

CC5A/CD5A/CD5BW

060

1.01

 

1.07

 

 

CC5A/CD5A/CD5BA

060

0.99

 

1.13

CD3(A,B)A

060

1.00

 

1.13

 

 

CC5A/CD5A/CD5BW

060

1.00

 

1.06

CJ5A/CK5A/CK5BA

060

1.00

 

1.11

 

 

CD3(A,B)A

060

0.99

 

1.13

CJ5A/CK5A/CK5BN

060

1.00

 

1.11

 

 

CE3AA

060

1.00

 

1.06

CJ5A/CK5A/CK5BX

060

1.00

 

1.02

 

 

CJ5A/CK5A/CK5BA

048

0.99

 

1.13

CK3BA

060

1.00

 

1.11

 

 

CK3BA

048

0.99

 

1.13

COILS + 355MAV060120 VARIABLE-SPEED FURNACE

 

 

 

060

0.99

 

1.12

CJ5A/CK5A/CK5BA

060

1.00

 

1.11

 

 

COILS + 333(B,J)AV060100 VARIABLE-SPEED FURNACE

CJ5A/CK5A/CK5BW

048

1.00

 

1.12

 

 

CC5A/CD5A/CD5BA

060

0.98

 

1.10

CJ5A/CK5A/CK5BX

060

1.00

 

1.07

 

 

CC5A/CD5A/CD5BW

060

0.99

 

1.03

CK3BA

048

1.00

 

1.12

 

 

CD3(A,B)A

060

0.98

 

1.10

 

060

1.00

 

1.11

 

 

CE3AA

060

0.99

 

1.04

 

 

 

See notes on page 34.

—33—

Page 33
Image 33
Bryant 697C warranty Indoor Heating Section