START-UP AND OPERATION

Power Cord

to EAC Terminals

Sample Furnace Circuit Board

Step 1—Checking Air Purifier OperationStep 2—EvolutiontControlFig. 8 - Power Indicator Use cable connector to secure

power cord to cabinet

Power Supply Connector

MAINTENANCE Power Supply Connector

Manual background Power Supply

Manual backgroundUse wire ties to secure power cord to power supply enclosure

Alternate Power Cord

Pass-Thru Hole

Power Cord

EAC-2 TERMINAL

W2

OFF

OFF

12 ON

 

LHT

 

 

Y1

DLY

 

3

 

 

DHUM

 

 

 

G

 

 

 

24V

 

 

 

TEST/TWIN

 

 

 

 

 

 

COMWW1

 

 

 

 

HUM PLT

ACRDJ

Y/Y2

 

 

 

0.5-AMP024 VAC

 

 

 

 

 

 

 

 

 

 

 

 

R

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

FUSE 3-AMP

 

 

 

 

 

 

T

 

 

 

 

 

S AT

 

 

 

ED

 

USEC-1 SEC-2

 

 

 

S

 

 

 

L

 

 

 

 

 

E

 

C

 

PL1

 

 

 

DO

 

 

 

EAC-2 NEUTRAL-L2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

BLW

 

 

1

 

BHI/LOR

 

 

BHT/CLR

HI HEAT

 

 

 

 

 

LO

 

 

COOL

1-AMP@115 VAC

HEAT

SPARE-1

SPARE-2

 

EAC-1

Use terminals to connect the power cord wires to the furnace EAC-1 & 2, & ground terminals

 

 

PL3

 

 

 

1

 

BLWR

 

 

 

IDR

HSIR

IDM

IHI/LOR

L1

1 PL2

 

 

PR-1

HSI

HI LO

 

GAPA

EAC-1 TERMINAL

 

A06030

Fig. 7 - Perfect Airt Purifier Electrical Connections

START-UP AND OPERATION

should use their discretion to select the most appropriate

 

option based on the initial system static pressure.

Step 1Checking Air Purifier Operation

Step 3Maximizing Performance

 

!WARNING

ELECTRICAL SHOCK HAZARD

Failure to follow this warning could result in personal injury or death.

Before installing or servicing system, always turn off main power to system. There may be more than one (1) disconnect switch.

a.Attach the Perfect Airt Purifier door to the cabinet. A magnet in the door (see Fig. 9) is used to activate a safe- ty switch in the power supply when the door is installed. The power supply will not energize the air purifier un- less the safety switch is activated.

b.Turn the HVAC system power on and adjust the thermostat or Evolutiont System Control to activate the system fan.

c.Turn the Perfect Airt Purifier power switch to on position.

d.The power indicator light above the Air Purifier power switch should illuminiate (see Fig. 8).

e.Check to ensure the light goes off when the Perfect Airt Purifier power switch is set to off, when the blower goes off, or when the HVAC system power is turned off.

Step 2EvolutiontControl

a.When the Perfect Airt Purifier is used with an Evolutiont Control, the Evolutiont Control can be configured to remind the homeowner when it is time to change the Perfect Airt Purifier cartridge. This maintenance reminder can be based on either the TrueSenset dirty filter algorithm or time. The installer

a.Maximum air purification performance is obtained when the furnace blower is set for continuous operation on the thermostat or Evolutiont Control.

Power Indicator

A06065

Fig. 8 - Power Indicator

MAINTENANCE

The Perfect Airt Purifier is designed to require no cleaning. Maintenance is limited to the replacement of the air purification cartridge. Frequency of air purifier cartridge replacement may vary depending on ductwork design and local environmental conditions.

To replace the air purifier cartridge, complete the following steps: