INSTALLATION

INSTALLATION

Step 6Check Perfect Airt Purifier Components

!CAUTION

CUT HAZARD

Failure to follow this caution may result in personal injury.

Sheet metal parts may have sharp edges or burrs. Use care and wear appropriate protective clothing and gloves when handling parts.

b. Carefully remove all items from the box.

Step 7Identify Mounting Location

a.Identify a mounting orientation for the Perfect Airt Purifier in the return air duct (see Fig. 3).

b.Ensure airflow direction through the Perfect Airt Purif- ier matches the arrows on the face of the air purifier cartridge. The Perfect Airt Purifier can be rotated 180 degrees to accommodate the cabinet orientation.

c.The location of the Perfect Airt Purifier should be readily accessible. Enough room should be provided for periodic replacement of the air purifier cartridges.

!WARNING

ELECTRICAL SHOCK AND UNIT DAMAGE HAZARD

Failure to follow this warning could result in personal injury or death.

Only a trained, experienced service person should install the Perfect Airt Purifier. A thorough check of the unit installation should be completed before unit operation. Before performing installation, service or maintenance operations on unit, turn off all power to unit. Tag disconnect switch with lockout tag.

GAPA

NOTE:

Mounting on this side requires the cabinet to be rotated 180° for correct air flow.

Airflow

Airflow

Airflow

Upflow Furnace with Side Return

Upflow Furnace with Bottom Mount

Downflow Furnace with Top Mount

Horizontal Application

A06067

Fig. 3 - Perfect Airt Purifier Cabinet Orientation