Cisco Systems MDS 9500 Series Removing and Installing Clock Modules, Cisco MDS 9513 clock module

Models: MDS 9500 Series

1 288
Download 288 pages 59.22 Kb
Page 156
Image 156

Chapter 2 Installing the Cisco MDS 9500 Series

Removing and Installing Clock Modules

Se n d d o c u m e n t a t i o n c o m m e n t s t o m d s f e e d b a ck - d o c @ c i s c o . c o m .

Installing a CompactFlash Card

To install a CompactFlash card, follow these steps:

Step 1 Position the CompactFlash card with the connector end of the card toward the slot. The connector end of the card is on the opposite side of the write-protection switch.

Step 2 Insert the card into the slot until the card is firmly seated in the connector at the back of the slot and the ejector button pops out toward you.

Caution The card does not insert all the way inside the slot; a portion of the card remains outside the slot. Do not attempt to force the card past this point or you could damage the connector pins.

Removing and Installing Clock Modules

The Cisco MDS 9500 Series includes one or more clock modules that are accessible from the back of the chassis. In the unlikely event of a clock module failure, Cisco recommends that the failed clock module be replaced during a maintenance window. The Cisco MDS 9513 and 9509 Directors have two field-replacable clock modules. The Cisco MDS 9506 Director has one field-replacable clock module. A separate procedure is provided for each type of director:

Removing a Clock Module from the Cisco MDS 9513 Director, page 2-77

Installing a Clock Module into the Cisco MDS 9513 Director, page 2-79

Removing a Clock Module from the Cisco MDS 9509 Director, page 2-80

Installing a Clock Module into the Cisco MDS 9509 Director, page 2-83

Removing a Clock Module from the Cisco MDS 9506 Director, page 2-83

Installing a Clock Module into the Cisco MDS 9506 Director, page 2-86

Before installing the clock module, check the contents of your kit. Table 2-5lists the contents of the clock module replacement kit, part number DS-C9513-CL.

Table 2-5

Contents of Cisco MDS 9513 Clock Module Replacement Kits

 

 

 

Quantity

Part Description

 

 

 

1

Cisco MDS 9513 clock module

 

 

 

1

Disposable ESD wrist strap

 

 

 

These tools are required to remove or install a clock module:

Number 2 Phillips screwdriver

Your own ESD-prevention equipment or the disposable grounding wrist strap included with all upgrade kits, field-replaceable units (FRUs), and spares

 

Cisco MDS 9500 Series Hardware Installation Guide

2-76

OL-17467-02

Page 156
Image 156
Cisco Systems MDS 9500 Series manual Removing and Installing Clock Modules, Installing a CompactFlash Card