Appendix A Migrating to Generation 3 8-Gbps Fibre Channel Switching Modules

Migration Procedures for the MDS 9513 Director

Se n d d o c u m e n t a t i o n c o m m e n t s t o m d s f e e d b a ck - d o c @ c i s c o . c o m .

Figure A-1 Captive Screws and Ejector Levers on the Fabric Module

1

2

3

4

 

 

 

2

 

 

 

5

 

 

 

188730

 

 

1

 

1

Captive screws

2

Ejector levers

3

Fabric slot 1 label

4

Fabric slot 2 label

5

Power LEDs

 

 

Step 9 Place the MDS 9513 Fabric 1 module on an antistatic surface.

Step 10 On the MDS 9513 Fabric 2 module to be installed, ensure that the ejector levers are completely open.

Step 11 Position the MDS 9513 Fabric 2 module in the chassis as follows:

a.Position the module in the empty slot. Ensure that you align the sides of the module carrier with the slot guides on each side of the slot.

b.Slide the module carefully into the slot until the EMI gasket along the top edge of the module contacts the module in the slot above it and both ejector levers close to approximately 45 degrees with respect to the front of the module. (See Figure A-2.)

Cisco MDS 9500 Series Hardware Installation Guide

 

OL-17467-02

A-7

 