Chapter 1 Product Overview

Power Supplies

Se n d d o c u m e n t a t i o n c o m m e n t s t o m d s f e e d b a ck - d o c @ c i s c o . c o m .

Cisco MDS 9506 Power Supplies

The Cisco MDS 9506 Director supports the following types of power supplies:

1900-W AC power supply (AC input and DC output)

1900-W DC power supply (DC input and DC output)

Power is supplied to the Cisco MDS 9506 power supplies though PEMs in the front of the chassis. The AC power requires an AC PEM, and the DC power requires a DC PEM.

The 1900-W AC and DC power supplies are similar in appearance (see Figure 1-11), except for the label that indicates whether the power supply is AC or DC.

Figure 1-11 Cisco MDS 9506 Power Supply (1900-W AC or DC)

1

FAN

INPUT

OUTPUT

OK

OK

FAIL

94996

2

1

Power supply LEDs

2

Captive screws

Table 1-3describes the power supply LEDs for the Cisco MDS 9509 and 9506 Directors.

Table 1-3

Power Supply LEDs for the Cisco MDS 9509 and 9506 Directors

 

 

 

 

LED

 

Status

Description

 

 

 

 

Input OK

 

Green

AC input is good and power supply is functioning

 

 

 

normally.

 

 

 

 

 

 

Off

Power supply is turned off or is not seated

 

 

 

properly in the chassis.

 

 

 

 

Fan OK

 

Green

Power supply fans are operating properly.

 

 

 

 

 

 

Off

Fan is not operating or power supply is off.

 

 

 

 

Output Fail

 

Red

Power supply is not in a stable state. If this

 

 

 

indication continues after initial power on, check

 

 

 

that all connections are secure, including the

 

 

 

system fan tray.

 

 

 

 

 

 

Off

Normal operation or power supply is turned off.

 

 

 

 

 

 