Chapter 2 Installing the Cisco MDS 9500 Series
Starting Up the Switch
Se n d d o c u m e n t a t i o n c o m m e n t s t o m d s f e e d b a ck - d o c @ c i s c o . c o m .
Providing Power to an AC Power Supply for the Cisco MDS 9513 Director
To provide power to an AC power supply in a Cisco MDS 9513 Director, follow these steps:
Step 1 Plug the power cable into the power supply, and tighten the screw on the cable retention device to ensure that the cable cannot be pulled out. Each power supply has two AC power connections (as shown in Figure
Figure 2-15 Cable Retention on the Power Supply
1
144528
2 2
1
Power switch
2
Cable retention
Step 2 Connect the other end of the power cable to an AC power source.
Step 3 Turn the power switch to the on () position on the power supply.
Step 4 Verify power supply operation by checking that the power supply LEDs are in the following states:
•INPUT OK LEDs are green.
•FAN OK LEDs are green.
•OUTPUT FAIL LED is off.
See Table
|