Appendix A Migrating to Generation 3 8-Gbps Fibre Channel Switching Modules

Migration Procedures for the MDS 9513 Director

Se n d d o c u m e n t a t i o n c o m m e n t s t o m d s f e e d b a ck - d o c @ c i s c o . c o m .

switch# show module

 

 

Mod Ports Module-Type

Model

Status

-------- -------------------------------- ------------------ ------------

 

7

0

Supervisor/Fabric-2

DS-X9530-SF2-K9

ha-standby

 

8

0

Supervisor/Fabric-2

DS-X9530-SF2-K9

active *

 

switch# out-of-service xbar 1

 

 

Step 5

Enter the show module xbar command to verify that the standby supervisor module is powered down.

Step 6

Attach a ESD wrist strap according to the instructions in the section “Preventing Electrostatic Discharge

 

Damage” section on page 2-19.

 

 

Step 7 Confirm that the LED light is red, which indicates that the module is powered off, and then loosen the two captive screws on the module being removed.

Step 8 Remove the module from the chassis as follows:

a.Place your thumbs on the top and bottom ejector levers and simultaneously rotate the levers outward to unseat the module from the midplane connector. (See Figure A-1)

b.Hold the front edge of the module and slide the module partially out of the slot. Do not touch the module circuitry.

Cisco MDS 9500 Series Hardware Installation Guide

 

A-6

OL-17467-02

 

 

 

Page 172
Image 172
Cisco Systems MDS 9500 Series manual Damage section on