Cisco Systems MDS 9500 Series manual Module Specifications, Physical Characteristics

Models: MDS 9500 Series

1 288
Download 288 pages 59.22 Kb
Page 216
Image 216

Appendix D Technical Specifications

Module Specifications

Se n d d o c u m e n t a t i o n c o m m e n t s t o m d s f e e d b a ck - d o c @ c i s c o . c o m .

Table D-4

Physical Specifications for the Cisco MDS 9506 Director (continued)

 

 

 

Description

Specification

 

 

 

Power supply

1900-W, AC input

 

1900-W, DC input

 

 

 

Airflow

300 lfm2 through system fan module, or 80 cfm3 per supervisor,

 

switching, or services module (total of 480 cfm if all slots are

 

filled).

 

Spacing requirements:

If installed in a cabinet, a minimum of 2.5 in. (6.4 cm) is required between the chassis air vents and the cabinet walls.

If installed in an open rack (no side panels), the horizontal distance required between the chassis and any devices that exhaust air towards the chassis is a minimum of 6 in.

(15.2 cm), and the distance required between the chassis air vents and any walls is a minimum of 2.5 in. (6.4 cm).

1.RU = rack unit; 1 RU = 1.75 in. (4.45 cm)

2.lfm = linear feet per minute

3.cfm = cubic feet per minute

Module Specifications

Table D-5lists the specifications for the Cisco MDS 9500 Series supervisor modules, services modules, and switching modules.

Table D-5 Cisco MDS 9500 Series Module Specifications

Description

Specification

Environmental Requirements

Temperature, certified for operation

32 to 104°F (0 to 40°C)

 

 

Temperature, designed and tested

32 to 130°F (0 to 55°C)

for operation

 

 

 

Temperature, ambient nonoperating

-40 to 167°F (-40 to 75°C)

and storage

 

 

 

Humidity (RH), ambient

10 to 90%

(noncondensing) operating

 

 

 

Altitude, certified for operation

0 to 6500 ft (0 to 2000 m)

 

 

Altitude, designed and tested for

-200 to 10000 ft (-60 to 3000 m)

operation

 

 

 

Physical Characteristics

 

 

 

Cisco MDS 9500 Series Hardware Installation Guide

 

D-4

OL-17467-02

 

 

 

Page 216
Image 216
Cisco Systems MDS 9500 Series manual Module Specifications, Physical Characteristics