Chapter 1 Product Overview
Switching Modules
Se n d d o c u m e n t a t i o n c o m m e n t s t o m d s f e e d b a ck - d o c @ c i s c o . c o m .
LEDs on the Generation 2 Switching Modules
Table
Table | LEDs for the Cisco MDS 9000 Family Generation 2 Fibre Channel Switching Modules | |||
|
|
|
|
|
LED | Status |
| Description | |
|
|
|
|
|
Status | Green |
| All diagnostics pass. The module is operational | |
|
|
| (normal initialization sequence). | |
|
|
|
|
|
| Orange |
| One of the following occurs or occurred: | |
|
|
| • The module is booting or running diagnostics | |
|
|
| (normal initialization sequence). | |
|
|
| • The inlet air temperature of the system has | |
|
|
| exceeded the maximum system operating | |
|
|
| temperature limit (a minor environmental | |
|
|
| warning). To ensure maximum product life, you | |
|
|
| should immediately correct the environmental | |
|
|
| temperature and restore the system to normal | |
|
|
| operation. | |
|
|
|
|
|
| Red |
| One of the following occurs or occurred: | |
|
|
| • The diagnostic test failed. The module is not | |
|
|
| operational because a fault occurred during the | |
|
|
| initialization sequence. | |
|
|
| • The inlet air temperature of the system has | |
|
|
| exceeded the safe operating temperature limits of | |
|
|
| the card (a major environmental warning). The | |
|
|
| card has been shut down to prevent permanent | |
|
|
| damage. | |
|
|
|
| |
Link | Solid green | Link is up. | ||
|
|
|
| |
| Intermittent | Link is up (traffic on port). | ||
| flashing green |
|
| |
|
|
|
| |
| Solid yellow | Link is disabled by software. | ||
|
|
|
| |
| Flashing | A fault condition exists. | ||
| yellow |
|
|
|
|
|
|
|
|
| Off |
| No link. | |
|
|
|
|
|